Filtered by vendor Philips
Subscribe
Total
104 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2015-2884 | 1 Philips | 1 In.sight B120\\37 | 2025-04-20 | 5.0 MEDIUM | 7.5 HIGH |
Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi. | |||||
CVE-2017-0199 | 2 Microsoft, Philips | 6 Office, Windows 7, Windows Server 2008 and 3 more | 2025-04-20 | 9.3 HIGH | 7.8 HIGH |
Microsoft Office 2007 SP3, Microsoft Office 2010 SP2, Microsoft Office 2013 SP1, Microsoft Office 2016, Microsoft Windows Vista SP2, Windows Server 2008 SP2, Windows 7 SP1, Windows 8.1 allow remote attackers to execute arbitrary code via a crafted document, aka "Microsoft Office/WordPad Remote Code Execution Vulnerability w/Windows API." | |||||
CVE-2017-14797 | 1 Philips | 2 Hue Bridge Bsb002, Hue Bridge Bsb002 Firmware | 2025-04-20 | 7.9 HIGH | 7.5 HIGH |
Lack of Transport Encryption in the public API in Philips Hue Bridge BSB002 SW 1707040932 allows remote attackers to read API keys (and consequently bypass the pushlink protection mechanism, and obtain complete control of the connected accessories) by leveraging the ability to sniff HTTP traffic on the local intranet network. | |||||
CVE-2015-2882 | 1 Philips | 1 In.sight B120\\37 | 2025-04-20 | 10.0 HIGH | 9.8 CRITICAL |
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account. | |||||
CVE-2017-14111 | 1 Philips | 2 Intellispace Cardiovascular, Xcelera | 2025-04-20 | 4.0 MEDIUM | 7.2 HIGH |
The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements. | |||||
CVE-2015-2883 | 1 Philips | 1 In.sight B120\\37 | 2025-04-20 | 3.5 LOW | 5.4 MEDIUM |
Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php. | |||||
CVE-2017-0143 | 3 Microsoft, Philips, Siemens | 28 Server Message Block, Windows 10 1507, Windows 10 1511 and 25 more | 2025-04-20 | 9.3 HIGH | 8.8 HIGH |
The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0144, CVE-2017-0145, CVE-2017-0146, and CVE-2017-0148. | |||||
CVE-2021-27497 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2025-04-17 | 7.5 HIGH | 6.5 MEDIUM |
Philips Vue PACS versions 12.2.x.x and prior does not use or incorrectly uses a protection mechanism that provides sufficient defense against directed attacks against the product. | |||||
CVE-2021-27493 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2025-04-17 | 6.4 MEDIUM | 6.1 MEDIUM |
Philips Vue PACS versions 12.2.x.x and prior does not ensure or incorrectly ensures structured messages or data are well formed and that certain security properties are met before being read from an upstream component or sent to a downstream component. | |||||
CVE-2021-39369 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2025-04-14 | N/A | 6.5 MEDIUM |
In Philips (formerly Carestream) Vue MyVue PACS through 12.2.x.x, the VideoStream function allows Path Traversal by authenticated users to access files stored outside of the web root. | |||||
CVE-2013-2808 | 1 Philips | 4 Xper Flex Cardio, Xper Information Management Physiomonitoring 5, Xper Information Management Vascular Monitoring 5 and 1 more | 2025-04-11 | 9.3 HIGH | N/A |
Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000. | |||||
CVE-2023-40704 | 1 Philips | 1 Vue Pacs | 2025-04-09 | N/A | 6.8 MEDIUM |
The product does not require unique and complex passwords to be created during installation. Using Philips's default password could jeopardize the PACS system if the password was hacked or leaked. An attacker could gain access to the database impacting system availability and data integrity. | |||||
CVE-2022-0922 | 1 Philips | 2 E-alert, E-alert Firmware | 2024-11-21 | 5.7 MEDIUM | 6.5 MEDIUM |
The software does not perform any authentication for critical system functionality. | |||||
CVE-2021-43552 | 1 Philips | 1 Patient Information Center Ix | 2024-11-21 | 2.1 LOW | 6.1 MEDIUM |
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03. | |||||
CVE-2021-43550 | 1 Philips | 3 Efficia Cm, Efficia Cm Firmware, Patient Information Center Ix | 2024-11-21 | 3.3 LOW | 5.9 MEDIUM |
The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0. | |||||
CVE-2021-43548 | 1 Philips | 1 Patient Information Center Ix | 2024-11-21 | 3.3 LOW | 6.5 MEDIUM |
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly. | |||||
CVE-2021-42744 | 1 Philips | 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more | 2024-11-21 | 2.1 LOW | 6.2 MEDIUM |
Philips MRI 1.5T and MRI 3T Version 5.x.x exposes sensitive information to an actor not explicitly authorized to have access. | |||||
CVE-2021-39376 | 1 Philips | 1 Tasy Electronic Medical Record | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter. | |||||
CVE-2021-39375 | 1 Philips | 1 Tasy Electronic Medical Record | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the WAdvancedFilter/getDimensionItemsByCode FilterValue parameter. | |||||
CVE-2021-33024 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2024-11-21 | 5.0 MEDIUM | 3.7 LOW |
Philips Vue PACS versions 12.2.x.x and prior transmits or stores authentication credentials, but it uses an insecure method susceptible to unauthorized interception and/or retrieval. |