Filtered by vendor Fujielectric
Subscribe
Total
102 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2017-9639 | 1 Fujielectric | 1 V-server | 2025-04-20 | 7.5 HIGH | 7.3 HIGH |
An issue was discovered in Fuji Electric V-Server Version 3.3.22.0 and prior. A memory corruption vulnerability has been identified (aka improper restriction of operations within the bounds of a memory buffer), which may allow remote code execution. | |||||
CVE-2017-9659 | 1 Fujielectric | 1 Monitouch V-sft | 2025-04-20 | 6.8 MEDIUM | 8.8 HIGH |
A Stack-Based Buffer Overflow issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. The stack-based buffer overflow vulnerability has been identified, which may cause a crash or allow remote code execution. | |||||
CVE-2017-9662 | 1 Fujielectric | 1 Monitouch V-sft | 2025-04-20 | 4.6 MEDIUM | 5.3 MEDIUM |
An Improper Privilege Management issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. Monitouch V-SFT is installed in a directory with weak access controls by default, which could allow an authenticated attacker with local access to escalate privileges. | |||||
CVE-2017-9660 | 1 Fujielectric | 1 Monitouch V-sft | 2025-04-20 | 6.8 MEDIUM | 8.8 HIGH |
A Heap-Based Buffer Overflow was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. A heap-based buffer overflow vulnerability has been identified, which may cause a crash or allow remote code execution. | |||||
CVE-2022-43448 | 1 Fujielectric | 2 Tellus, V-sft | 2025-04-10 | N/A | 7.8 HIGH |
Out-of-bounds write vulnerability in V-SFT v6.1.7.0 and earlier and TELLUS v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted image file. | |||||
CVE-2022-46360 | 1 Fujielectric | 2 Tellus, V-sft | 2025-04-10 | N/A | 7.8 HIGH |
Out-of-bounds read vulnerability in V-SFT v6.1.7.0 and earlier and TELLUS v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted image file. | |||||
CVE-2022-41645 | 1 Fujielectric | 1 V-server | 2025-04-10 | N/A | 7.8 HIGH |
Out-of-bounds read vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file. | |||||
CVE-2022-47908 | 1 Fujielectric | 1 V-server | 2025-04-10 | N/A | 7.8 HIGH |
Stack-based buffer overflow vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file. | |||||
CVE-2022-47317 | 1 Fujielectric | 1 V-server | 2025-04-10 | N/A | 7.8 HIGH |
Out-of-bounds write vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file. | |||||
CVE-2023-29498 | 1 Fujielectric | 1 Frenic Rhc Loader | 2025-01-03 | N/A | 5.5 MEDIUM |
Improper restriction of XML external entity reference (XXE) vulnerability exists in FRENIC RHC Loader v1.1.0.3 and earlier. If a user opens a specially crafted project file, sensitive information on the system where the affected product is installed may be disclosed. | |||||
CVE-2023-29167 | 1 Fujielectric | 1 Frenic Rhc Loader | 2025-01-03 | N/A | 7.8 HIGH |
Out-of-bound reads vulnerability exists in FRENIC RHC Loader v1.1.0.3. If a user opens a specially crafted FNE file, sensitive information on the system where the affected product is installed may be disclosed or arbitrary code may be executed. | |||||
CVE-2023-29160 | 1 Fujielectric | 1 Frenic Rhc Loader | 2025-01-03 | N/A | 7.8 HIGH |
Stack-based buffer overflow vulnerability exists in FRENIC RHC Loader v1.1.0.3. If a user opens a specially crafted FNE file, sensitive information on the system where the affected product is installed may be disclosed or arbitrary code may be executed. | |||||
CVE-2023-32538 | 1 Fujielectric | 2 Tellus, Tellus Lite | 2024-12-23 | N/A | 7.8 HIGH |
Stack-based buffer overflow vulnerability exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted SIM2 file may lead to information disclosure and/or arbitrary code execution. This vulnerability is different from CVE-2023-32273 and CVE-2023-32201. | |||||
CVE-2023-32288 | 1 Fujielectric | 2 Tellus, Tellus Lite | 2024-12-23 | N/A | 7.8 HIGH |
Out-of-bounds read vulnerability exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted SIM file may lead to information disclosure and/or arbitrary code execution. | |||||
CVE-2023-32276 | 1 Fujielectric | 2 Tellus, Tellus Lite | 2024-12-23 | N/A | 7.8 HIGH |
Stack-based buffer overflow vulnerability exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted V8 file may lead to information disclosure and/or arbitrary code execution. | |||||
CVE-2023-32273 | 1 Fujielectric | 2 Tellus, Tellus Lite | 2024-12-23 | N/A | 7.8 HIGH |
Stack-based buffer overflow vulnerability exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted SIM2 file may lead to information disclosure and/or arbitrary code execution. This vulnerability is different from CVE-2023-32538 and CVE-2023-32201. | |||||
CVE-2023-32270 | 1 Fujielectric | 2 Tellus, Tellus Lite | 2024-12-23 | N/A | 7.8 HIGH |
Access of memory location after end of buffer issue exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted V8 file may lead to information disclosure and/or arbitrary code execution. | |||||
CVE-2023-32201 | 1 Fujielectric | 2 Tellus, Tellus Lite | 2024-12-23 | N/A | 7.8 HIGH |
Stack-based buffer overflow vulnerability exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted SIM2 file may lead to information disclosure and/or arbitrary code execution. This vulnerability is different from CVE-2023-32538 and CVE-2023-32273. | |||||
CVE-2023-31239 | 1 Fujielectric | 1 V-server | 2024-12-23 | N/A | 7.8 HIGH |
Stack-based buffer overflow vulnerability in V-Server v4.0.15.0 and V-Server Lite v4.0.15.0 and earlier allows an attacker to execute arbitrary code by having user open a specially crafted VPR file. | |||||
CVE-2023-32542 | 1 Fujielectric | 2 Tellus, Tellus Lite | 2024-12-12 | N/A | 7.8 HIGH |
Out-of-bounds read vulnerability exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted V8 file may lead to information disclosure and/or arbitrary code execution. |