CVE-2017-7920 1 Abb 4 Vsn300, Vsn300 Firmware, Vsn300 For React and 1 more 2025-04-20 5.0 MEDIUM 7.5 HIGH
An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating.
CVE-2017-7916 1 Abb 4 Vsn300, Vsn300 Firmware, Vsn300 For React and 1 more 2025-04-20 4.0 MEDIUM 6.5 MEDIUM
A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. The web application does not properly restrict privileges of the Guest account. A malicious user may be able to gain access to configuration information that should be restricted.
CVE-2016-4516 1 Abb 1 Pcm600 2025-04-12 2.1 LOW 3.3 LOW
ABB PCM600 before 2.7 improperly stores the main application password after a password change, which allows local users to obtain sensitive information via unspecified vectors.
CVE-2016-4511 1 Abb 1 Pcm600 2025-04-12 1.9 LOW 2.8 LOW
ABB PCM600 before 2.7 uses an improper hash algorithm for the main application password, which makes it easier for local users to obtain sensitive cleartext information by leveraging read access to the ACTConfig configuration file.
CVE-2016-4524 1 Abb 1 Pcm600 2025-04-12 2.1 LOW 6.5 MEDIUM
ABB PCM600 before 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors.
CVE-2014-5430 1 Abb 2 Robotstudio, Test Signal Viewer 2025-04-12 6.9 MEDIUM N/A
Untrusted search path vulnerability in ABB RobotStudio 5.6x before 5.61.02 and Test Signal Viewer 1.5 allows local users to gain privileges via a Trojan horse DLL that is accessed as a result of incorrect DLL configuration by an optional installation program.
CVE-2016-4527 1 Abb 1 Pcm600 2025-04-12 1.9 LOW 3.3 LOW
ABB PCM600 before 2.7 improperly stores PCM600 authentication credentials, which allows local users to obtain sensitive information via unspecified vectors.
CVE-2016-2281 1 Abb 1 Panel Builder 800 2025-04-12 6.0 MEDIUM 7.2 HIGH
Untrusted search path vulnerability in ABB Panel Builder 800 5.1 allows local users to gain privileges via a Trojan horse DLL in the current working directory.
CVE-2012-0245 1 Abb 10 Interlink Module, Irc5 Opc Server, Pc Sdk and 7 more 2025-04-11 10.0 HIGH N/A
Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet.
CVE-2012-1801 1 Abb 7 Interlink Module, Quickteach, Robotstudio Lite and 4 more 2025-04-11 7.7 HIGH N/A
Multiple stack-based buffer overflows in (1) COM and (2) ActiveX controls in ABB WebWare Server, WebWare SDK, Interlink Module, S4 OPC Server, QuickTeach, RobotStudio S4, and RobotStudio Lite allow remote attackers to execute arbitrary code via crafted input data.
CVE-2013-5021 2 Abb, Ni 5 Datamanager, Labview, Labwindows and 2 more 2025-04-11 9.3 HIGH N/A
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.
CVE-2024-51547 1 Abb 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more 2025-04-10 N/A 9.8 CRITICAL
Use of Hard-coded Credentials vulnerability in ABB ASPECT-Enterprise, ABB NEXUS Series, ABB MATRIX Series.This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03.
CVE-2024-51544 1 Abb 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more 2025-04-10 N/A 8.2 HIGH
Service Control vulnerabilities allow access to service restart requests and vm configuration settings.  Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
CVE-2024-51542 1 Abb 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more 2025-04-10 N/A 8.2 HIGH
Configuration Download vulnerabilities allow access to dependency configuration information.  Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
CVE-2024-51546 1 Abb 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more 2025-04-10 N/A 7.5 HIGH
Credentials Disclosure vulnerabilities allow access to on board project back-up bundles.  Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
CVE-2024-11316 1 Abb 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more 2025-04-10 N/A 7.5 HIGH
Fileszie Check vulnerabilities allow a malicious user to bypass size limits or overload to the product.  Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
CVE-2024-6784 1 Abb 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more 2025-04-10 N/A 9.9 CRITICAL
Server-Side Request Forgery vulnerabilities were found providing a potential for access to unauthorized resources and unintended information disclosure.  Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
CVE-2024-11317 1 Abb 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more 2025-04-10 N/A 10.0 CRITICAL
Session Fixation vulnerabilities allow an attacker to fix a users session identifier before login providing an opportunity for session takeover on a product.  Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
CVE-2008-2474 1 Abb 1 Pcu400 2025-04-09 10.0 HIGH N/A
Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface.
CVE-2022-3573 2 Abb, Gitlab 2 Drive Composer, Gitlab 2025-04-08 N/A 5.4 MEDIUM
An issue has been discovered in GitLab CE/EE affecting all versions starting from 15.4 before 15.5.7, all versions starting from 15.6 before 15.6.4, all versions starting from 15.7 before 15.7.2. Due to the improper filtering of query parameters in the wiki changes page, an attacker can execute arbitrary JavaScript on the self-hosted instances running without strict CSP.