Vulnerabilities (CVE)

Filtered by vendor Schneider-electric Subscribe
Total 758 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-5680 1 Schneider-electric 1 Ecostruxure Foxboro Dcs Control Core Services 2024-11-21 N/A 7.1 HIGH
CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver.
CVE-2024-5679 1 Schneider-electric 1 Ecostruxure Foxboro Dcs Control Core Services 2024-11-21 N/A 7.1 HIGH
CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, or kernel memory leak when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver.
CVE-2024-5560 1 Schneider-electric 7 Sage 1410, Sage 1430, Sage 1450 and 4 more 2024-11-21 N/A 5.3 MEDIUM
CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request.
CVE-2024-5559 1 Schneider-electric 2 Powerlogic P5, Powerlogic P5 Firmware 2024-11-21 N/A 6.1 MEDIUM
CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists that could cause denial of service, device reboot, or an attacker gaining full control of the relay when a specially crafted reset token is entered into the front panel of the device.
CVE-2024-5558 1 Schneider-electric 4 Spacelogic As-b, Spacelogic As-b Firmware, Spacelogic As-p and 1 more 2024-11-21 N/A 6.4 MEDIUM
CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could cause escalation of privileges when an attacker abuses a limited admin account.
CVE-2024-5557 1 Schneider-electric 4 Spacelogic As-b, Spacelogic As-b Firmware, Spacelogic As-p and 1 more 2024-11-21 N/A 4.5 MEDIUM
CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause exposure of SNMP credentials when an attacker has access to the controller logs.
CVE-2024-5313 1 Schneider-electric 2 Evlink Home, Evlink Home Firmware 2024-11-21 N/A 6.5 MEDIUM
CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH interface over the product network interface. This does not allow to directly exploit the product or make any unintended operation as the SSH interface access is protected by an authentication mechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts to perform a potential denial of service attack on the exposed SSH interface.
CVE-2024-5056 1 Schneider-electric 6 Bmxnoe0100, Bmxnoe0100 Firmware, Bmxnoe0110 and 3 more 2024-11-21 N/A 6.5 MEDIUM
CWE-552: Files or Directories Accessible to External Parties vulnerability exists which may prevent user to update the device firmware and prevent proper behavior of the webserver when specific files or directories are removed from the filesystem.
CVE-2024-37040 1 Schneider-electric 7 Sage 1410, Sage 1430, Sage 1450 and 4 more 2024-11-21 N/A 5.4 MEDIUM
CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request.
CVE-2024-37039 1 Schneider-electric 7 Sage 1410, Sage 1430, Sage 1450 and 4 more 2024-11-21 N/A 5.9 MEDIUM
CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request.
CVE-2024-37038 1 Schneider-electric 7 Sage 1410, Sage 1430, Sage 1450 and 4 more 2024-11-21 N/A 7.5 HIGH
CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.
CVE-2024-37037 1 Schneider-electric 7 Sage 1410, Sage 1430, Sage 1450 and 4 more 2024-11-21 N/A 8.1 HIGH
CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request.
CVE-2024-37036 1 Schneider-electric 7 Sage 1410, Sage 1430, Sage 1450 and 4 more 2024-11-21 N/A 9.8 CRITICAL
CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.
CVE-2024-2747 1 Schneider-electric 1 Easergy Studio 2024-11-21 N/A 7.8 HIGH
CWE-428: Unquoted search path or element vulnerability exists in Easergy Studio, which could cause privilege escalation when a valid user replaces a trusted file name on the system and reboots the machine.
CVE-2024-2602 1 Schneider-electric 1 Foxrtu Station 2024-11-21 N/A 7.3 HIGH
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could result in remote code execution when an authenticated user executes a saved project file that has been tampered by a malicious actor.
CVE-2024-0865 1 Schneider-electric 1 Ecostruxure It Gateway 2024-11-21 N/A 7.8 HIGH
CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege escalation when logged in as a non-administrative user.
CVE-2023-7032 1 Schneider-electric 1 Easergy Studio 2024-11-21 N/A 7.8 HIGH
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker logged in with a user level account to gain higher privileges by providing a harmful serialized object.
CVE-2023-6407 2 Microsoft, Schneider-electric 6 Windows 10 1507, Windows 11 21h2, Windows Server 2016 and 3 more 2024-11-21 N/A 5.3 MEDIUM
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker.
CVE-2023-6032 1 Schneider-electric 4 Galaxy Vl, Galaxy Vl Firmware, Galaxy Vs and 1 more 2024-11-21 N/A 5.3 MEDIUM
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause a file system enumeration and file download when an attacker navigates to the Network Management Card via HTTPS.
CVE-2023-5987 1 Schneider-electric 1 Ecostruxure Power Monitoring Expert 2024-11-21 N/A 6.1 MEDIUM
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.