Vulnerabilities (CVE)

Filtered by vendor Schneider-electric Subscribe
Total 758 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2017-9970 1 Schneider-electric 1 Struxureon Gateway 2024-11-21 9.0 HIGH 7.2 HIGH
A remote code execution vulnerability exists in Schneider Electric's StruxureOn Gateway versions 1.1.3 and prior. Uploading a zip which contains carefully crafted metadata allows for the file to be uploaded to any directory on the host machine information which could lead to remote code execution.
CVE-2017-9969 1 Schneider-electric 1 Igss Mobile 2024-11-21 2.1 LOW 6.7 MEDIUM
An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information.
CVE-2017-9968 1 Schneider-electric 1 Igss Mobile 2024-11-21 4.3 MEDIUM 5.9 MEDIUM
A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack.
CVE-2017-9967 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 4.6 MEDIUM 7.8 HIGH
A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured resulting in weak security.
CVE-2017-9966 1 Schneider-electric 1 Pelco Videoxpert 2024-11-21 7.1 HIGH 7.1 HIGH
A privilege escalation vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. By replacing certain files, an unauthorized user can obtain system privileges and the inserted code would execute at an elevated privilege level.
CVE-2017-9965 1 Schneider-electric 1 Pelco Videoxpert 2024-11-21 5.0 MEDIUM 5.8 MEDIUM
An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files.
CVE-2017-9964 1 Schneider-electric 1 Pelco Videoxpert 2024-11-21 5.8 MEDIUM 6.9 MEDIUM
A Path Traversal issue was discovered in Schneider Electric Pelco VideoXpert Enterprise all versions prior to 2.1. By sniffing communications, an unauthorized person can execute a directory traversal attack resulting in authentication bypass or session hijack.
CVE-2017-9963 1 Schneider-electric 1 Powerscada Anywhere 2024-11-21 5.8 MEDIUM 8.1 HIGH
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.
CVE-2017-9637 1 Schneider-electric 1 Ampla Manufacturing Execution System 2024-11-21 1.9 LOW 4.1 MEDIUM
Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.
CVE-2017-9635 1 Schneider-electric 1 Ampla Manufacturing Execution System 2024-11-21 1.9 LOW 3.9 LOW
Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.
CVE-2017-6021 2 Aveva, Schneider-electric 2 Clearscada, Clearscada 2024-11-21 5.0 MEDIUM 7.5 HIGH
In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of commands and data packets to the ClearSCADA server that can cause the ClearSCADA server process and ClearSCADA communications driver processes to terminate. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
CVE-2015-6462 1 Schneider-electric 22 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 19 more 2024-11-21 3.5 LOW 5.4 MEDIUM
Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.
CVE-2015-6461 1 Schneider-electric 22 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 19 more 2024-11-21 5.5 MEDIUM 5.4 MEDIUM
Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page.
CVE-2015-1014 1 Schneider-electric 3 Citectscada, Opc Factory Server, Scada Expert Vijeo Citect 2024-11-21 4.4 MEDIUM 7.3 HIGH
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.
CVE-2024-10575 1 Schneider-electric 1 Ecostruxure It Gateway 2024-11-19 N/A 9.8 CRITICAL
CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on the network and potentially impacting connected devices.
CVE-2024-9409 1 Schneider-electric 6 Powerlogic Pm5320, Powerlogic Pm5320 Firmware, Powerlogic Pm5340 and 3 more 2024-11-19 N/A 7.5 HIGH
CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.
CVE-2024-8422 1 Schneider-electric 1 Zelio Soft 2 2024-10-16 N/A 7.8 HIGH
CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when application user opens a malicious Zelio Soft 2 project file.
CVE-2024-8306 1 Schneider-electric 2 Vijeo Designer, Vijeo Designer Embedded In Ecostruxure Machine Expert 2024-09-18 N/A 7.8 HIGH
CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized access, loss of confidentiality, integrity and availability of the workstation when non-admin authenticated user tries to perform privilege escalation by tampering with the binaries.