Filtered by vendor Schneider-electric
Subscribe
Total
758 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2015-3977 | 1 Schneider-electric | 1 Imt25 Magnetic Flow Dtm | 2025-04-12 | 7.7 HIGH | N/A |
Buffer overflow in Schneider Electric IMT25 Magnetic Flow DTM before 1.500.004 for the HART Protocol allows remote authenticated users to execute arbitrary code or cause a denial of service (memory corruption) via a crafted HART reply. | |||||
CVE-2014-0789 | 1 Schneider-electric | 5 Opc Factory Server Tlxcdlfofs, Opc Factory Server Tlxcdltofs, Opc Factory Server Tlxcdluofs and 2 more | 2025-04-12 | 7.8 HIGH | N/A |
Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions. | |||||
CVE-2015-0998 | 2 Aveva, Schneider-electric | 2 Aveva Edge, Wonderware Intouch 2014 | 2025-04-12 | 3.3 LOW | N/A |
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network. | |||||
CVE-2014-8390 | 1 Schneider-electric | 1 Vampset | 2025-04-12 | 4.4 MEDIUM | N/A |
Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file. | |||||
CVE-2014-0754 | 1 Schneider-electric | 86 171ccc96020, 171ccc96020 Firmware, 171ccc96020c and 83 more | 2025-04-12 | 10.0 HIGH | N/A |
Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103x Exec before 5.7, TSXETY5103x Exec before 5.9, TSXP57x ETYPort Exec before 5.7, and TSXP57x Ethernet Copro Exec before 5.5 allows remote attackers to visit arbitrary resources via a crafted HTTP request. | |||||
CVE-2016-4529 | 1 Schneider-electric | 3 M171, M172, Somachine Hvac Firmware | 2025-04-12 | 7.5 HIGH | 7.3 HIGH |
An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting) flag. | |||||
CVE-2014-9206 | 1 Schneider-electric | 1 Device Type Manager | 2025-04-12 | 6.9 MEDIUM | N/A |
Stack-based buffer overflow in Device Type Manager (DTM) 3.1.6 and earlier for Schneider Electric Invensys SRD Control Valve Positioner devices 960 and 991 allows local users to gain privileges via a malformed DLL file. | |||||
CVE-2015-3962 | 1 Schneider-electric | 1 Struxureware Building Expert Multi-purpose Management | 2025-04-12 | 5.0 MEDIUM | N/A |
Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remote attackers to discover credentials by sniffing the network. | |||||
CVE-2014-0759 | 1 Schneider-electric | 1 Floating License Manager | 2025-04-12 | 6.9 MEDIUM | N/A |
Unquoted Windows search path vulnerability in Schneider Electric Floating License Manager 1.0.0 through 1.4.0 allows local users to gain privileges via a Trojan horse application with a name composed of an initial substring of a path that contains a space character. | |||||
CVE-2015-3940 | 1 Schneider-electric | 1 Wonderware System Platform 2014 | 2025-04-12 | 6.9 MEDIUM | N/A |
Untrusted search path vulnerability in Schneider Electric Wonderware System Platform before 2014 R2 Patch 01 allows local users to gain privileges via a Trojan horse DLL in an unspecified directory. | |||||
CVE-2015-0996 | 2 Aveva, Schneider-electric | 2 Aveva Edge, Wonderware Intouch 2014 | 2025-04-12 | 2.1 LOW | N/A |
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password. | |||||
CVE-2016-2291 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2025-04-12 | 4.3 MEDIUM | 6.5 MEDIUM |
Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allow remote attackers to execute arbitrary code or cause a denial of service (out-of-bounds read) via unspecified vectors. | |||||
CVE-2016-4520 | 1 Schneider-electric | 1 Pelco Digital Sentry Video Management System Firmware | 2025-04-12 | 10.0 HIGH | 9.8 CRITICAL |
Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14 has hardcoded credentials, which allows remote attackers to obtain access, and consequently execute arbitrary code, via unspecified vectors. | |||||
CVE-2014-5411 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-04-12 | 3.5 LOW | N/A |
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors. | |||||
CVE-2014-5413 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-04-12 | 5.0 MEDIUM | N/A |
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm. | |||||
CVE-2014-9198 | 1 Schneider-electric | 5 Etg3000 Factorycast Hmi Gateway Firmware, Tsxetg3000, Tsxetg3010 and 2 more | 2025-04-12 | 10.0 HIGH | N/A |
The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session. | |||||
CVE-2014-9197 | 1 Schneider-electric | 5 Etg3000 Factorycast Hmi Gateway Firmware, Tsxetg3000, Tsxetg3010 and 2 more | 2025-04-12 | 7.8 HIGH | N/A |
The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request. | |||||
CVE-2015-8561 | 1 Schneider-electric | 1 Proclima | 2025-04-12 | 6.8 MEDIUM | N/A |
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918. | |||||
CVE-2015-3963 | 2 Schneider-electric, Windriver | 14 Sage 1210, Sage 1230, Sage 1250 and 11 more | 2025-04-12 | 5.8 MEDIUM | N/A |
Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value. | |||||
CVE-2015-7918 | 1 Schneider-electric | 1 Proclima | 2025-04-12 | 6.8 MEDIUM | N/A |
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561. |