Filtered by vendor Deltaww
Subscribe
Total
233 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-0251 | 1 Deltaww | 1 Diascreen | 2024-11-21 | N/A | 7.8 HIGH |
Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to a buffer overflow through improper restrictions of operations within memory, which could allow an attacker to remotely execute arbitrary code. | |||||
CVE-2023-0250 | 1 Deltaww | 1 Diascreen | 2024-11-21 | N/A | 7.8 HIGH |
Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code. | |||||
CVE-2023-0249 | 1 Deltaww | 1 Diascreen | 2024-11-21 | N/A | 7.8 HIGH |
Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to out-of-bounds write, which may allow an attacker to remotely execute arbitrary code. | |||||
CVE-2023-0124 | 1 Deltaww | 1 Dopsoft | 2024-11-21 | N/A | 7.8 HIGH |
Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to an out-of-bounds write, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software. | |||||
CVE-2023-0123 | 1 Deltaww | 1 Dopsoft | 2024-11-21 | N/A | 7.8 HIGH |
Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software. | |||||
CVE-2022-4634 | 1 Deltaww | 2 Cncsoft, Screeneditor | 2024-11-21 | N/A | 7.8 HIGH |
All versions prior to Delta Electronic’s CNCSoft version 1.01.34 (running ScreenEditor versions 1.01.5 and prior) are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code. | |||||
CVE-2022-4616 | 1 Deltaww | 2 Dx-3021l9, Dx-3021l9 Firmware | 2024-11-21 | N/A | 7.2 HIGH |
The webserver in Delta DX-3021 versions prior to 1.24 is vulnerable to command injection through the network diagnosis page. This vulnerability could allow a remote unauthenticated user to add files, delete files, and change file permissions. | |||||
CVE-2022-43775 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | N/A | 9.8 CRITICAL |
The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system. | |||||
CVE-2022-43774 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | N/A | 9.8 CRITICAL |
The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system. | |||||
CVE-2022-43506 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | N/A | 8.8 HIGH |
SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2022-43457 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | N/A | 8.8 HIGH |
SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2022-43452 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | N/A | 8.8 HIGH |
SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2022-43447 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | N/A | 8.8 HIGH |
SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2022-41779 | 1 Deltaww | 1 Infrasuite Device Master | 2024-11-21 | N/A | 8.8 HIGH |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution. | |||||
CVE-2022-41778 | 1 Deltaww | 1 Infrasuite Device Master | 2024-11-21 | N/A | 9.8 CRITICAL |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. | |||||
CVE-2022-41776 | 1 Deltaww | 1 Infrasuite Device Master | 2024-11-21 | N/A | 7.5 HIGH |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords. | |||||
CVE-2022-41775 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | N/A | 8.8 HIGH |
SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2022-41773 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | N/A | 8.8 HIGH |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | |||||
CVE-2022-41772 | 1 Deltaww | 1 Infrasuite Device Master | 2024-11-21 | N/A | 9.8 CRITICAL |
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution. | |||||
CVE-2022-41702 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | N/A | 8.7 HIGH |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API. |