Vulnerabilities (CVE)

Filtered by vendor Deltaww Subscribe
Total 266 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-0444 1 Deltaww 1 Infrasuite Device Master 2025-04-03 N/A 8.8 HIGH
A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A default user 'User', which is in the 'Read Only User' group, can view the password of another default user 'Administrator', which is in the 'Administrator' group. This allows any lower privileged user to log in as an administrator.
CVE-2024-25574 1 Deltaww 1 Diaenergie 2025-02-27 N/A 8.8 HIGH
SQL injection vulnerability exists in GetDIAE_usListParameters.
CVE-2024-39354 1 Deltaww 1 Diascreen 2025-01-30 N/A 7.8 HIGH
If an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overflow in CEtherIPTagItem can be exploited, allowing the attacker to remotely execute arbitrary code.
CVE-2024-47131 1 Deltaww 1 Diascreen 2025-01-30 N/A 7.8 HIGH
If an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overflow in BACnetObjectInfo can be exploited, allowing the attacker to remotely execute arbitrary code.
CVE-2024-39605 1 Deltaww 1 Diascreen 2025-01-30 N/A 7.8 HIGH
If an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overflow in BACnetParameter can be exploited, allowing the attacker to remotely execute arbitrary code.
CVE-2024-34033 1 Deltaww 1 Diaenergie 2025-01-30 N/A 8.8 HIGH
Delta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.
CVE-2024-34032 1 Deltaww 1 Diaenergie 2025-01-30 N/A 8.8 HIGH
Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.
CVE-2024-34031 1 Deltaww 1 Diaenergie 2025-01-30 N/A 8.8 HIGH
Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.
CVE-2023-34316 1 Deltaww 1 Infrasuite Device Master 2025-01-27 N/A 6.5 MEDIUM
​An attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents.
CVE-2023-30765 1 Deltaww 1 Infrasuite Device Master 2025-01-27 N/A 8.8 HIGH
​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation.
CVE-2024-25937 1 Deltaww 1 Diaenergie 2025-01-24 N/A 8.8 HIGH
SQL injection vulnerability exists in the script DIAE_tagHandler.ashx.
CVE-2023-0432 1 Deltaww 2 Dx-2100l1-cn, Dx-2100l1-cn Firmware 2025-01-17 N/A 9.0 CRITICAL
The web configuration service of the affected device contains an authenticated command injection vulnerability. It can be used to execute system commands on the operating system (OS) from the device in the context of the user "root." If the attacker has credentials for the web service, then the device could be fully compromised.
CVE-2024-39883 1 Deltaww 1 Cncsoft-g2 2024-11-21 N/A 8.8 HIGH
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
CVE-2024-39882 1 Deltaww 1 Cncsoft-g2 2024-11-21 N/A 8.8 HIGH
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
CVE-2024-39881 1 Deltaww 1 Cncsoft-g2 2024-11-21 N/A 8.8 HIGH
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
CVE-2024-39880 1 Deltaww 1 Cncsoft-g2 2024-11-21 N/A 7.8 HIGH
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
CVE-2024-28029 1 Deltaww 1 Diaenergie 2024-11-21 N/A 8.8 HIGH
Privileges are not fully verified server-side, which can be abused by a user with limited privileges to bypass authorization and access privileged functionality.
CVE-2023-5944 1 Deltaww 1 Dopsoft 2024-11-21 N/A 7.8 HIGH
Delta Electronics DOPSoft is vulnerable to a stack-based buffer overflow, which may allow for arbitrary code execution if an attacker can lead a legitimate user to execute a specially crafted file.
CVE-2023-5461 1 Deltaww 1 Wplsoft 2024-11-21 2.6 LOW 3.7 LOW
A vulnerability was found in Delta Electronics WPLSoft 2.51. It has been classified as problematic. Affected is an unknown function of the component Modbus Handler. The manipulation leads to cleartext transmission of sensitive information. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-241584. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-5460 1 Deltaww 1 Wplsoft 2024-11-21 2.7 LOW 3.5 LOW
A vulnerability was found in Delta Electronics WPLSoft up to 2.51 and classified as problematic. This issue affects some unknown processing of the component Modbus Data Packet Handler. The manipulation leads to heap-based buffer overflow. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-241583. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.