Filtered by vendor Schneider-electric
Subscribe
Total
758 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2018-7765 | 1 Schneider-electric | 1 U.motion Builder | 2024-11-21 | 6.8 MEDIUM | 8.8 HIGH |
The vulnerability exists within processing of track_import_export.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the object_id input parameter. | |||||
CVE-2018-7764 | 1 Schneider-electric | 1 U.motion Builder | 2024-11-21 | 4.3 MEDIUM | 4.3 MEDIUM |
The vulnerability exists within runscript.php applet in Schneider Electric U.motion Builder software versions prior to v1.3.4. There is a directory traversal vulnerability in the processing of the 's' parameter of the applet. | |||||
CVE-2018-7763 | 1 Schneider-electric | 1 U.motion Builder | 2024-11-21 | 4.3 MEDIUM | 4.3 MEDIUM |
The vulnerability exists within css.inc.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The 'css' parameter contains a directory traversal vulnerability. | |||||
CVE-2018-7762 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow. | |||||
CVE-2018-7761 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution. | |||||
CVE-2018-7760 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization. | |||||
CVE-2018-7759 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied. | |||||
CVE-2018-7758 | 1 Schneider-electric | 46 Micom P141, Micom P141 Firmware, Micom P142 and 43 more | 2024-11-21 | 3.3 LOW | 6.5 MEDIUM |
A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network communication in case of TCP/IP open requests on port 20000 (DNP3oE) if an older TCI/IP session is still open with identical IP address and port number. | |||||
CVE-2018-7522 | 1 Schneider-electric | 2 Triconex Tricon Mp 3008, Triconex Tricon Mp 3008 Firmware | 2024-11-21 | 7.2 HIGH | 6.7 MEDIUM |
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states. | |||||
CVE-2018-7246 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2024-11-21 | 5.0 MEDIUM | 9.8 CRITICAL |
A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. he integrated web server (Port 80/443/TCP) of the affected devices could allow remote attackers to discover an administrative account. If default on device, it is not using a SSL in settings and if multiple request of the page "Access Control" (IP-address device/ups/pas_cont.htm) account data will be sent in cleartext | |||||
CVE-2018-7245 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2024-11-21 | 6.4 MEDIUM | 9.1 CRITICAL |
An improper authorization vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to change UPS control and shutdown parameters or other critical settings without authorization. | |||||
CVE-2018-7244 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
An information disclosure vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to obtain sensitive device information if network access was obtained. | |||||
CVE-2018-7243 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to get a full access to device, bypassing the authorization system. | |||||
CVE-2018-7242 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | 5.0 MEDIUM | 9.8 CRITICAL |
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks. | |||||
CVE-2018-7241 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. | |||||
CVE-2018-7240 | 1 Schneider-electric | 26 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 23 more | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
A vulnerability exists in Schneider Electric's Modicon Quantum in all versions of the communication modules which could allow arbitrary code execution. An FTP command used to upgrade the firmware of the module can be misused to cause a denial of service, or in extreme cases, to load a malicious firmware. | |||||
CVE-2018-7239 | 1 Schneider-electric | 13 Atv12 Dtm, Atv212 Dtm, Atv312 Dtm and 10 more | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A DLL hijacking vulnerability exists in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code. | |||||
CVE-2018-7238 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code. | |||||
CVE-2018-7237 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2024-11-21 | 6.4 MEDIUM | 9.1 CRITICAL |
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file' | |||||
CVE-2018-7236 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2024-11-21 | 5.8 MEDIUM | 8.1 HIGH |
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service. |