Vulnerabilities (CVE)

Total 316927 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2017-12788 1 Metinfo 1 Metinfo 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
Multiple cross-site scripting (XSS) vulnerabilities in admin/index.php in Metinfo 5.3.18 allows remote attackers to inject arbitrary web script or HTML via the (1) class1 parameter or the (2) anyid parameter.
CVE-2017-12778 1 Qbittorrent 1 Qbittorrent 2024-11-21 3.6 LOW 7.1 HIGH
The UI Lock feature in qBittorrent version 3.3.15 is vulnerable to Authentication Bypass, which allows Attack to gain unauthorized access to qBittorrent functions by tampering the affected flag value of the config file at the C:\Users\<username>\Roaming\qBittorrent pathname. The attacker must change the value of the "locked" attribute to "false" within the "Locking" stanza. NOTE: This is an intended behavior. See https://github.com/qbittorrent/qBittorrent/wiki/I-forgot-my-UI-lock-password
CVE-2017-12761 1 Webfile Explorer Project 1 Webfile Explorer 2024-11-21 5.0 MEDIUM 7.5 HIGH
http://codecanyon.net/user/Endober WebFile Explorer 1.0 is affected by: SQL Injection. The impact is: Arbitrary File Download (remote). The component is: $file = $_GET['id'] in download.php. The attack vector is: http://speicher.example.com/envato/codecanyon/demo/web-file-explorer/download.php?id=WebExplorer/../config.php.
CVE-2017-12760 1 Ynetinteractive 1 Mobiketa 2024-11-21 6.5 MEDIUM 8.8 HIGH
Ynet Interactive - http://demo.ynetinteractive.com/mobiketa/ Mobiketa 4.0 is affected by: SQL Injection. The impact is: Code execution (remote).
CVE-2017-12759 1 Ynetinteractive 1 Soa School Management 2024-11-21 7.5 HIGH 9.8 CRITICAL
Ynet Interactive - http://demo.ynetinteractive.com/soa/ SOA School Management 3.0 is affected by: SQL Injection. The impact is: Code execution (remote).
CVE-2017-12758 1 Joomlaextensions 1 Component Appointment 2024-11-21 7.5 HIGH 9.8 CRITICAL
https://www.joomlaextensions.co.in/ Joomla! Component Appointment 1.1 is affected by: SQL Injection. The impact is: Code execution (remote). The component is: com_appointment component.
CVE-2017-12757 1 Ambittechnologies 12 Itech B2b Script, Itech Business Networking Script, Itech Caregiver Script and 9 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
Certain Ambit Technologies Pvt. Ltd products are affected by: SQL Injection. This affects iTech B2B Script 4.42i and Tech Business Networking Script 8.26i and Tech Caregiver Script 2.71i and Tech Classifieds Script 7.41i and Tech Dating Script 3.40i and Tech Freelancer Script 5.27i and Tech Image Sharing Script 4.13i and Tech Job Script 9.27i and Tech Movie Script 7.51i and Tech Multi Vendor Script 6.63i and Tech Social Networking Script 3.08i and Tech Travel Script 9.49. The impact is: Code execution (remote).
CVE-2017-12729 1 Moxa 1 Softcms Lab View 2024-11-21 7.5 HIGH 9.8 CRITICAL
A SQL Injection issue was discovered in Moxa SoftCMS Live Viewer through 1.6. An improper neutralization of special elements used in an SQL command ('SQL Injection') vulnerability has been identified. Attackers can exploit this vulnerability to access SoftCMS without knowing the user's password.
CVE-2017-12726 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2024-11-21 7.5 HIGH 7.3 HIGH
A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module.
CVE-2017-12725 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2024-11-21 6.8 MEDIUM 5.6 MEDIUM
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection.
CVE-2017-12724 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2024-11-21 6.8 MEDIUM 8.1 HIGH
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections.
CVE-2017-12723 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2024-11-21 4.3 MEDIUM 3.7 LOW
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.
CVE-2017-12722 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2024-11-21 5.0 MEDIUM 5.3 MEDIUM
An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module.
CVE-2017-12721 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2024-11-21 4.3 MEDIUM 5.9 MEDIUM
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle (MITM) attack.
CVE-2017-12720 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2024-11-21 6.8 MEDIUM 8.1 HIGH
An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections.
CVE-2017-12718 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2024-11-21 6.8 MEDIUM 8.1 HIGH
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.
CVE-2017-12716 1 Abbott 8 Accent, Accent Firmware, Accent Mri and 5 more 2024-11-21 3.3 LOW 6.5 MEDIUM
Abbott Laboratories Accent and Anthem pacemakers manufactured prior to Aug 28, 2017 transmit unencrypted patient information via RF communications to programmers and home monitoring units. Additionally, the Accent and Anthem pacemakers store the optional patient information without encryption. CVSS v3 base score: 3.1, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
CVE-2017-12714 1 Abbott 14 Accent, Accent Firmware, Accent Mri and 11 more 2024-11-21 6.1 MEDIUM 6.5 MEDIUM
Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
CVE-2017-12712 1 Abbott 14 Accent, Accent Firmware, Accent Mri and 11 more 2024-11-21 8.3 HIGH 8.8 HIGH
The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
CVE-2017-12701 1 Cpap 2 Luna Cpap Machine, Luna Cpap Machine Firmware 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
BMC Medical Luna CPAP Machines released prior to July 1, 2017, contain an improper input validation vulnerability which may allow an authenticated attacker to crash the CPAP's Wi-Fi module resulting in a denial-of-service condition.