Vulnerabilities (CVE)

Filtered by CWE-912
Total 51 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-6045 2024-11-21 N/A 8.8 HIGH
Certain models of D-Link wireless routers contain an undisclosed factory testing backdoor. Unauthenticated attackers on the local area network can force the device to enable Telnet service by accessing a specific URL and can log in by using the administrator credentials obtained from analyzing the firmware.
CVE-2024-5633 2024-11-21 N/A N/A
Longse model LBH30FE200W cameras, as well as products based on this device, provide an unrestricted access for an attacker located in the same local network to an undocumented binary service CoolView on one of the ports.  An attacker with a knowledge of the available commands is able to perform read/write operations on the device's memory, which might result in e.g. bypassing telnet login and obtaining full access to the device.
CVE-2024-3016 2024-11-21 N/A 9.1 CRITICAL
NEC Platforms DT900 and DT900S Series 5.0.0.0 – v5.3.4.4, v5.4.0.0 – v5.6.0.20 allows an attacker to access a non-documented the system settings to change settings via local network with unauthenticated user.
CVE-2024-33583 2024-11-21 N/A 3.3 LOW
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected application contains a hidden configuration item to enable debug functionality. This could allow an authenticated local attacker to gain insight into the internal configuration of the deployment.
CVE-2024-22044 2024-11-21 N/A 7.5 HIGH
A vulnerability has been identified in SENTRON 3KC ATC6 Expansion Module Ethernet (3KC9000-8TL75) (All versions). Affected devices expose an unused, unstable http service at port 80/tcp on the Modbus-TCP Ethernet. This could allow an attacker on the same Modbus network to create a denial of service condition that forces the device to reboot.
CVE-2023-6614 1 Typecho 1 Typecho 2024-11-21 3.3 LOW 2.7 LOW
A vulnerability classified as problematic was found in Typecho 1.2.1. Affected by this vulnerability is an unknown functionality of the file /admin/manage-pages.php of the component Page Handler. The manipulation leads to backdoor. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-247249 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-4467 1 Poly 2 Trio 8800, Trio 8800 Firmware 2024-11-21 6.5 MEDIUM 6.2 MEDIUM
A vulnerability was found in Poly Trio 8800 7.2.6.0019 and classified as critical. Affected by this issue is some unknown functionality of the component Test Automation Mode. The manipulation leads to backdoor. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-249260.
CVE-2023-42134 1 Paxtechnology 3 A50, A920 Pro, Paydroid 2024-11-21 N/A 6.8 MEDIUM
PAX Android based POS devices with PayDroid_8.1.0_Sagittarius_V11.1.45_20230314 or earlier can allow the signed partition overwrite and subsequently local code execution via hidden command. The attacker must have physical USB access to the device in order to exploit this vulnerability.
CVE-2023-40158 1 Cbc 46 Dr-16f42a, Dr-16f42a Firmware, Dr-16f45at and 43 more 2024-11-21 N/A 8.8 HIGH
Hidden functionality vulnerability in the CBC products allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter its settings. As for the affected products/versions, see the detailed information provided by the vendor. Note that NR4H, NR8H, NR16H series and DR-16F, DR-8F, DR-4F, DR-16H, DR-8H, DR-4H, DR-4M41 series are no longer supported, therefore updates for those products are not provided.
CVE-2023-25183 1 Snapone 2 Orvc, Ovrc-300-pro 2024-11-21 N/A 8.3 HIGH
In Snap One OvrC Pro versions prior to 7.2, when logged into the superuser account, a new functionality appears that could allow users to execute arbitrary commands on the hub device.
CVE-2022-3843 1 Wago 2 852-111\/000-001, 852-111\/000-001 Firmware 2024-11-21 N/A 9.1 CRITICAL
In WAGO Unmanaged Switch (852-111/000-001) in firmware version 01 an undocumented configuration interface without authorization allows an remote attacker to read system information and configure a limited set of parameters.
CVE-2022-3203 1 Oringnet 4 Iap-420, Iap-420\+, Iap-420\+ Firmware and 1 more 2024-11-21 N/A 9.8 CRITICAL
On ORing net IAP-420(+) with FW version 2.0m a telnet server is enabled by default and cannot permanently be disabled. You can connect to the device via LAN or WiFi with hardcoded credentials and get an administrative shell. These credentials are reset to defaults with every reboot.
CVE-2022-38452 1 Netgear 2 Rbs750, Rbs750 Firmware 2024-11-21 N/A 7.2 HIGH
A command execution vulnerability exists in the hidden telnet service functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability.
CVE-2022-36429 1 Netgear 2 Rbs750, Rbs750 Firmware 2024-11-21 N/A 7.2 HIGH
A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
CVE-2021-4229 1 Ua-parser-js Project 1 Ua-parser-js 2024-11-21 7.6 HIGH 5.0 MEDIUM
A vulnerability was found in ua-parser-js 0.7.29/0.8.0/1.0.0. It has been rated as critical. This issue affects the crypto mining component which introduces a backdoor. Upgrading to version 0.7.30, 0.8.1 and 1.0.1 is able to address this issue. It is recommended to upgrade the affected component.
CVE-2021-43987 1 Myscada 1 Mypro 2024-11-21 7.5 HIGH 9.8 CRITICAL
An additional, nondocumented administrative account exists in mySCADA myPRO Versions 8.20.0 and prior that is not exposed through the web interface, which cannot be deleted or changed through the regular web interface.
CVE-2021-24867 1 Accesspressthemes 93 Accessbuddy, Accesspress Anonymous Post, Accesspress Basic and 90 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
Numerous Plugins and Themes from the AccessPress Themes (aka Access Keys) vendor are backdoored due to their website being compromised. Only plugins and themes downloaded via the vendor website are affected, and those hosted on wordpress.org are not. However, all of them were updated or removed to avoid any confusion
CVE-2020-3352 1 Cisco 1 Firepower Threat Defense 2024-11-21 1.9 LOW 5.5 MEDIUM
A vulnerability in the CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to access hidden commands. The vulnerability is due to the presence of undocumented configuration commands. An attacker could exploit this vulnerability by performing specific steps that make the hidden commands accessible. A successful exploit could allow the attacker to make configuration changes to various sections of an affected device that should not be exposed to CLI access.
CVE-2020-28593 1 Cosori 2 Cs158-af, Cs158-af Firmware 2024-11-21 6.8 MEDIUM 8.1 HIGH
A unauthenticated backdoor exists in the configuration server functionality of Cosori Smart 5.8-Quart Air Fryer CS158-AF 1.1.0. A specially crafted JSON object can lead to code execution. An attacker can send a malicious packet to trigger this vulnerability.
CVE-2020-16204 1 Redlion 4 N-tron 702-w, N-tron 702-w Firmware, N-tron 702m12-w and 1 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
The affected product is vulnerable due to an undocumented interface found on the device, which may allow an attacker to execute commands as root on the device on the N-Tron 702-W / 702M12-W (all versions).