Vulnerabilities (CVE)

Filtered by CWE-121
Total 1926 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-6749 1 Zephyrproject 1 Zephyr 2025-01-22 N/A 8.0 HIGH
Unchecked length coming from user input in settings shell
CVE-2024-31496 1 Fortinet 3 Fortianalyzer, Fortianalyzer Big Data, Fortimanager 2025-01-21 N/A 6.7 MEDIUM
A stack-based buffer overflow vulnerability [CWE-121] in Fortinet FortiManager version 7.4.0 through 7.4.2 and before 7.2.5, FortiAnalyzer version 7.4.0 through 7.4.2 and before 7.2.5 and FortiAnalyzer-BigData 7.4.0 and before 7.2.7 allows a privileged attacker to execute unauthorized code or commands via crafted CLI requests.
CVE-2020-12820 1 Fortinet 1 Fortios 2025-01-21 N/A 5.4 MEDIUM
Under non-default configuration, a stack-based buffer overflow in FortiOS version 6.0.10 and below, version 5.6.12 and below may allow a remote attacker authenticated to the SSL VPN to crash the FortiClient NAC daemon (fcnacd) and potentially execute arbitrary code via requesting a large FortiClient file name. We are not aware of proof of concept code successfully achieving the latter.
CVE-2024-4064 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4065 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4066 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3905 1 Tenda 2 Ac500, Ac500 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3906 1 Tenda 2 Ac500, Ac500 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3910 1 Tenda 2 Ac500, Ac500 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3875 1 Tenda 2 F1202, F1202 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3876 1 Tenda 2 F1202, F1202 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3877 1 Tenda 2 F1202, F1202 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3878 1 Tenda 2 F1202, F1202 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4166 1 Tenda 2 4g300, 4g300 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda 4G300 1.01.42 and classified as critical. Affected by this vulnerability is the function sub_41E858. The manipulation of the argument GO/page leads to stack-based buffer overflow. The attack can be launched remotely. The identifier VDB-261985 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4167 1 Tenda 2 4g300, 4g300 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub_422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4168 1 Tenda 2 4g300, 4g300 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4169 1 Tenda 2 4g300, 4g300 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4170 1 Tenda 2 4g300, 4g300 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-0566 2025-01-19 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda AC15 15.13.07.13. This affects the function formSetDevNetName of the file /goform/SetDevNetName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-3907 1 Tenda 2 Ac500, Ac500 Firmware 2025-01-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.