CVE-2024-23126

A maliciously crafted CATPART file when parsed CC5Dll.dll through Autodesk applications can be used to cause a Stack-based Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process.
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*

Configuration 2 (hide)

OR cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*

Configuration 3 (hide)

OR cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*

Configuration 4 (hide)

OR cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*

Configuration 5 (hide)

OR cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*

Configuration 6 (hide)

OR cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*

Configuration 7 (hide)

OR cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*

Configuration 8 (hide)

OR cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*

Configuration 9 (hide)

OR cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*

History

11 Apr 2025, 15:57

Type Values Removed Values Added
CWE CWE-787
References () https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0002 - () https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0002 - Vendor Advisory
References () https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0004 - () https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0004 - Vendor Advisory
CPE cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
First Time Autodesk civil 3d
Autodesk autocad Electrical
Autodesk autocad Mep
Autodesk autocad Map 3d
Autodesk autocad Plant 3d
Autodesk autocad Architecture
Autodesk autocad Mechanical
Autodesk advance Steel
Autodesk
Autodesk autocad

27 Jan 2025, 18:15

Type Values Removed Values Added
CVSS v2 : unknown
v3 : 7.5
v2 : unknown
v3 : 7.8
Summary (en) A maliciously crafted CATPART file in CC5Dll.dll when parsed through Autodesk AutoCAD can be used to cause a Stack-based Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process. (en) A maliciously crafted CATPART file when parsed CC5Dll.dll through Autodesk applications can be used to cause a Stack-based Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process.

Information

Published : 2024-02-22 03:15

Updated : 2025-04-11 15:57


NVD link : CVE-2024-23126

Mitre link : CVE-2024-23126

CVE.ORG link : CVE-2024-23126


JSON object : View

Products Affected

autodesk

  • autocad_architecture
  • advance_steel
  • autocad
  • autocad_plant_3d
  • civil_3d
  • autocad_map_3d
  • autocad_mep
  • autocad_mechanical
  • autocad_electrical
CWE
CWE-121

Stack-based Buffer Overflow

CWE-787

Out-of-bounds Write