CVE-2024-33687 1 Omron 110 Nj-pa3001, Nj-pa3001 Firmware, Nj-pd3001 and 107 more 2025-03-13 N/A 7.5 HIGH
Insufficient verification of data authenticity issue exists in NJ Series CPU Unit all versions and NX Series CPU Unit all versions. If a user program in the affected product is altered, the product may not be able to detect the alteration.
CVE-2022-34151 1 Omron 113 Na5-12w, Na5-12w Firmware, Na5-15w and 110 more 2024-11-21 6.8 MEDIUM 8.1 HIGH
Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller.
CVE-2022-33971 1 Omron 104 Nj-pa3001, Nj-pa3001 Firmware, Nj-pd3001 and 101 more 2024-11-21 5.4 MEDIUM 7.5 HIGH
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication between the controller and the specific software used by OMRON internally to cause a denial-of-service (DoS) condition or execute a malicious program.
CVE-2022-33208 1 Omron 113 Na5-12w, Na5-12w Firmware, Na5-15w and 110 more 2024-11-21 6.8 MEDIUM 8.1 HIGH
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software 'Sysmac Studio' and/or a Programmable Terminal (PT) to access the controller.