Total
78 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2017-16923 | 1 Tenda | 6 Ac15, Ac15 Firmware, Ac18 and 3 more | 2025-04-20 | 8.3 HIGH | 8.8 HIGH |
Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input. | |||||
CVE-2017-16936 | 1 Tenda | 6 Ac15, Ac15 Firmware, Ac18 and 3 more | 2025-04-20 | 3.3 LOW | 6.5 MEDIUM |
Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring. | |||||
CVE-2024-30891 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-10 | N/A | 8.8 HIGH |
A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution. | |||||
CVE-2024-33835 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-10 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function. | |||||
CVE-2024-33181 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-07 | N/A | 8.8 HIGH |
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceMac parameter at ip/goform/addWifiMacFilter. | |||||
CVE-2024-41630 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-07 | N/A | 7.6 HIGH |
Stack-based buffer overflow vulnerability in Tenda AC18 V15.03.3.10_EN allows a remote attacker to execute arbitrary code via the ssid parameter at ip/goform/fast_setting_wifi_set. | |||||
CVE-2023-24170 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-28 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/fromSetWirelessRepeat. | |||||
CVE-2023-24169 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-28 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_0007343c. | |||||
CVE-2023-24167 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-28 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/add_white_node. | |||||
CVE-2023-24166 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-28 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet. | |||||
CVE-2023-24165 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-28 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/initIpAddrInfo. | |||||
CVE-2023-24164 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-28 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_000c2318. | |||||
CVE-2024-57582 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-22 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the startIP parameter in the formSetPPTPServer function. | |||||
CVE-2024-57579 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-19 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the limitSpeedUp parameter in the formSetClientState function. | |||||
CVE-2024-57581 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-18 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function. | |||||
CVE-2024-57580 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-18 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function. | |||||
CVE-2024-57578 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-17 | N/A | 8.8 HIGH |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the funcpara1 parameter in the formSetCfm function. | |||||
CVE-2024-57577 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-17 | N/A | 5.7 MEDIUM |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | |||||
CVE-2024-34974 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-17 | N/A | 8.2 HIGH |
Tenda AC18 v15.03.05.19 is vulnerable to Buffer Overflow in the formSetPPTPServer function via the endIp parameter. | |||||
CVE-2024-28545 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-13 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload function. |