Filtered by vendor Siemens
Subscribe
Total
1913 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2014-9369 | 1 Siemens | 6 Spc4000, Spc4000 Firmware, Spc5000 and 3 more | 2025-04-12 | 7.8 HIGH | N/A |
Siemens SPC controllers SPC4000, SPC5000, and SPC6000 before 3.6.0 allow remote attackers to cause a denial of service (device restart) via crafted packets. | |||||
CVE-2014-2908 | 1 Siemens | 6 Simatic S7 Cpu-1211c, Simatic S7 Cpu 1200 Firmware, Simatic S7 Cpu 1212c and 3 more | 2025-04-12 | 4.3 MEDIUM | N/A |
Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
CVE-2016-8564 | 1 Siemens | 1 Automation License Manager | 2025-04-12 | 6.4 MEDIUM | 6.5 MEDIUM |
SQL injection vulnerability in Siemens Automation License Manager (ALM) before 5.3 SP3 Update 1 allows remote attackers to execute arbitrary SQL commands via crafted traffic to TCP port 4410. | |||||
CVE-2016-2201 | 1 Siemens | 15 Simatic S7-1500 Cpu Firmware, Simatic S7-1511-1 Pn Cpu, Simatic S7-1511c-1 Pn Cpu and 12 more | 2025-04-12 | 5.0 MEDIUM | 5.3 MEDIUM |
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102. | |||||
CVE-2015-2822 | 1 Siemens | 1 Wincc | 2025-04-12 | 4.3 MEDIUM | N/A |
Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102. | |||||
CVE-2014-2733 | 1 Siemens | 1 Sinema Server | 2025-04-12 | 5.0 MEDIUM | N/A |
Siemens SINEMA Server before 12 SP1 allows remote attackers to cause a denial of service (web-interface outage) via crafted HTTP requests to port (1) 4999 or (2) 80. | |||||
CVE-2016-5744 | 1 Siemens | 1 Simatic Wincc | 2025-04-12 | 5.0 MEDIUM | 7.5 HIGH |
Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets. | |||||
CVE-2014-2731 | 1 Siemens | 1 Sinema Server | 2025-04-12 | 9.3 HIGH | N/A |
Multiple unspecified vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to execute arbitrary code via HTTP traffic to port (1) 4999 or (2) 80. | |||||
CVE-2016-9155 | 1 Siemens | 30 Ccid1445-dn18, Ccid1445-dn18 Firmware, Ccid1445-dn28 and 27 more | 2025-04-12 | 5.0 MEDIUM | 9.8 CRITICAL |
The following SIEMENS branded IP Camera Models CCMW3025, CVMW3025-IR, CFMW3025 prior to version 1.41_SP18_S1; CCPW3025, CCPW5025 prior to version 0.1.73_S1; CCMD3025-DN18 prior to version v1.394_S1; CCID1445-DN18, CCID1445-DN28, CCID1145-DN36, CFIS1425, CCIS1425, CFMS2025, CCMS2025, CVMS2025-IR, CFMW1025, CCMW1025 prior to version v2635_SP1 could allow an attacker with network access to the web server to obtain administrative credentials under certain circumstances. | |||||
CVE-2016-5849 | 1 Siemens | 1 Sicam Pas\/pqs | 2025-04-12 | 1.9 LOW | 2.5 LOW |
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage. | |||||
CVE-2014-2251 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2025-04-12 | 8.3 HIGH | N/A |
The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors. | |||||
CVE-2015-5717 | 1 Siemens | 1 Compas | 2025-04-12 | 5.8 MEDIUM | N/A |
The Siemens COMPAS Mobile application before 1.6 for Android does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate. | |||||
CVE-2016-8672 | 1 Siemens | 8 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 5 more | 2025-04-12 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server delivers cookies without the "secure" flag. Modern browsers interpreting the flag would mitigate potential data leakage in case of clear text transmission. | |||||
CVE-2014-2247 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2025-04-12 | 5.8 MEDIUM | N/A |
The integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject headers via unspecified vectors. | |||||
CVE-2014-8478 | 1 Siemens | 9 Scalance X-300, Scalance X-300 Series Firmware, Scalance X-300eec and 6 more | 2025-04-12 | 7.8 HIGH | N/A |
The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests. | |||||
CVE-2015-5698 | 1 Siemens | 2 Simatic S7 1200 Cpu, Simatic S7 1200 Cpu Firmware | 2025-04-12 | 7.5 HIGH | N/A |
Cross-site request forgery (CSRF) vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors. | |||||
CVE-2014-2256 | 1 Siemens | 6 Simatic S7 Cpu-1211c, Simatic S7 Cpu 1200 Firmware, Simatic S7 Cpu 1212c and 3 more | 2025-04-12 | 7.8 HIGH | N/A |
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets, a different vulnerability than CVE-2014-2257. | |||||
CVE-2014-2248 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2025-04-12 | 4.3 MEDIUM | N/A |
Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors. | |||||
CVE-2014-4686 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-12 | 6.8 MEDIUM | N/A |
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030. | |||||
CVE-2014-0160 | 13 Broadcom, Canonical, Debian and 10 more | 35 Symantec Messaging Gateway, Ubuntu Linux, Debian Linux and 32 more | 2025-04-12 | 5.0 MEDIUM | 7.5 HIGH |
The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug. |