CVE-2023-2263 1 Rockwellautomation 2 Kinetix 5700, Kinetix 5700 Firmware 2024-11-21 N/A 7.5 HIGH
The Rockwell Automation Kinetix 5700 DC Bus Power Supply Series A is vulnerable to CIP fuzzing.  The new ENIP connections cannot be established if impacted by this vulnerability,  which prohibits operational capabilities of the device resulting in a denial-of-service attack.
CVE-2023-2262 1 Rockwellautomation 66 1756-en2f Series A, 1756-en2f Series A Firmware, 1756-en2f Series B and 63 more 2024-11-21 N/A 9.8 CRITICAL
A buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device.
CVE-2023-2072 1 Rockwellautomation 2 Powermonitor 1000, Powermonitor 1000 Firmware 2024-11-21 N/A 8.8 HIGH
The Rockwell Automation PowerMonitor 1000 contains stored cross-site scripting vulnerabilities within the web page of the product.  The vulnerable pages do not require privileges to access and can be injected with code by an attacker which could be used to leverage an attack on an authenticated user resulting in remote code execution and potentially the complete loss of confidentiality, integrity, and availability of the product.
CVE-2023-2071 1 Rockwellautomation 2 Factorytalk View, Panelview Plus 2024-11-21 N/A 9.8 CRITICAL
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets.  The device has the functionality, through a CIP class, to execute exported functions from libraries.  There is a routine that restricts it to execute specific functions from two dynamic link library files.  By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.
CVE-2023-29464 1 Rockwellautomation 1 Factorytalk Linx 2024-11-21 N/A 8.2 HIGH
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
CVE-2023-29463 1 Rockwellautomation 1 Pavilion8 2024-11-21 N/A 8.8 HIGH
The JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users’ session data and or log users out of their session.
CVE-2023-29031 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2024-11-21 N/A 7.0 HIGH
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
CVE-2023-29030 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2024-11-21 N/A 7.0 HIGH
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
CVE-2023-29025 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2024-11-21 N/A 4.7 MEDIUM
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page.
CVE-2023-29024 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2024-11-21 N/A 5.5 MEDIUM
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product A cross site scripting vulnerability was discovered that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
CVE-2023-29023 1 Rockwellautomation 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more 2024-11-21 N/A 7.0 HIGH
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
CVE-2023-27857 1 Rockwellautomation 1 Thinmanager 2024-11-21 N/A 7.5 HIGH
In affected versions, a heap-based buffer over-read condition occurs when the message field indicates more data than is present in the message field in Rockwell Automation's ThinManager ThinServer.  An unauthenticated remote attacker can exploit this vulnerability to crash ThinServer.exe due to a read access violation.
CVE-2023-27856 1 Rockwellautomation 1 Thinmanager 2024-11-21 N/A 7.5 HIGH
In affected versions, path traversal exists when processing a message of type 8 in Rockwell Automation's ThinManager ThinServer. An unauthenticated remote attacker can exploit this vulnerability to download arbitrary files on the disk drive where ThinServer.exe is installed.
CVE-2023-27855 1 Rockwellautomation 1 Thinmanager 2024-11-21 N/A 9.8 CRITICAL
In affected versions, a path traversal exists when processing a message in Rockwell Automation's ThinManager ThinServer. An unauthenticated remote attacker could potentially exploit this vulnerability to upload arbitrary files to any directory on the disk drive where ThinServer.exe is installed. The attacker could overwrite existing executable files with attacker-controlled, malicious contents, potentially causing remote code execution.
CVE-2023-1834 1 Rockwellautomation 2 Kinetix 5500, Kinetix 5500 Firmware 2024-11-21 N/A 9.4 CRITICAL
Rockwell Automation was made aware that Kinetix 5500 drives, manufactured between May 2022 and January 2023, and are running v7.13 may have the telnet and FTP ports open by default.  This could potentially allow attackers unauthorized access to the device through the open ports.
CVE-2023-0755 3 Ge, Ptc, Rockwellautomation 9 Digital Industrial Gateway Server, Kepware Server, Kepware Serverex and 6 more 2024-11-21 N/A 9.8 CRITICAL
The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.
CVE-2023-0754 3 Ge, Ptc, Rockwellautomation 9 Digital Industrial Gateway Server, Kepware Server, Kepware Serverex and 6 more 2024-11-21 N/A 9.8 CRITICAL
The affected products are vulnerable to an integer overflow or wraparound, which could  allow an attacker to crash the server and remotely execute arbitrary code.
CVE-2023-0027 1 Rockwellautomation 1 Modbus Tcp Server Add On Instructions 2024-11-21 N/A 5.3 MEDIUM
Rockwell Automation Modbus TCP Server AOI prior to 2.04.00 is vulnerable to an unauthorized user sending a malformed message that could cause the controller to respond with a copy of the most recent response to the last valid request. If exploited, an unauthorized user could read the connected device’s Modbus TCP Server AOI information.
CVE-2022-46670 1 Rockwellautomation 10 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 7 more 2024-11-21 N/A 7.1 HIGH
Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution.  The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website.
CVE-2022-3752 1 Rockwellautomation 10 Compact Guardlogix 5380, Compact Guardlogix 5380 Firmware, Compactlogix 5380 and 7 more 2024-11-21 N/A 8.6 HIGH
An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic loading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online and continue normal operation.