Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 1164 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2025-25505 1 Tenda 2 Ac6, Ac6 Firmware 2025-04-10 N/A 6.5 MEDIUM
Tenda AC6 15.03.05.16_multi is vulnerable to Buffer Overflow in the sub_452A4 function.
CVE-2025-25507 1 Tenda 2 Ac6, Ac6 Firmware 2025-04-10 N/A 6.5 MEDIUM
There is a RCE vulnerability in Tenda AC6 15.03.05.16_multi. In the formexeCommand function, the parameter cmdinput will cause remote command execution.
CVE-2025-25510 1 Tenda 2 Ac8, Ac8 Firmware 2025-04-10 N/A 6.5 MEDIUM
Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the get_parentControl_list_Info function.
CVE-2025-1851 1 Tenda 2 Ac7, Ac7 Firmware 2025-04-10 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-25632 1 Tenda 2 Ac15, Ac15 Firmware 2025-04-09 N/A 9.8 CRITICAL
Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet.
CVE-2024-51116 1 Tenda 2 Ac6, Ac6 Firmware 2025-04-09 N/A 8.8 HIGH
Tenda AC6 v2.0 V15.03.06.50 was discovered to contain a buffer overflow in the function 'formSetPPTPServer'.
CVE-2024-44859 1 Tenda 2 Fh1201, Fh1201 Firmware 2025-04-09 N/A 8.0 HIGH
Tenda FH1201 v1.2.0.14 has a stack buffer overflow vulnerability in `formWrlExtraGet`.
CVE-2025-22949 1 Tenda 2 Ac9, Ac9 Firmware 2025-04-09 N/A 9.8 CRITICAL
Tenda ac9 v1.0 firmware v15.03.05.19 is vulnerable to command injection in /goform/SetSambaCfg, which may lead to remote arbitrary code execution.
CVE-2025-22946 1 Tenda 2 Ac9, Ac9 Firmware 2025-04-09 N/A 9.8 CRITICAL
Tenda ac9 v1.0 firmware v15.03.05.19 contains a stack overflow vulnerability in /goform/SetOnlineDevName, which may lead to remote arbitrary code execution.
CVE-2024-57483 1 Tenda 2 I24, I24 Firmware 2025-04-09 N/A 9.8 CRITICAL
Tenda i24 V2.0.0.5 is vulnerable to Buffer Overflow in the addWifiMacFilter function.
CVE-2025-3161 1 Tenda 2 Ac10, Ac10 Firmware 2025-04-09 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function ShutdownSetAdd of the file /goform/ShutdownSetAdd. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-32282 1 Tenda 2 Fh1202, Fh1202 Firmware 2025-04-09 N/A 6.3 MEDIUM
Tenda FH1202 v1.2.0.14(408) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
CVE-2024-32302 1 Tenda 2 Fh1202, Fh1202 Firmware 2025-04-09 N/A 6.3 MEDIUM
Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.
CVE-2024-32315 1 Tenda 2 Fh1202, Fh1202 Firmware 2025-04-09 N/A 4.7 MEDIUM
Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
CVE-2023-46060 1 Tenda 2 Ac500, Ac500 Firmware 2025-04-09 N/A 7.5 HIGH
A Buffer Overflow vulnerability in Tenda AC500 v.2.0.1.9 allows a remote attacker to cause a denial of service via the port parameter at the goform/setVlanInfo component.
CVE-2024-32305 1 Tenda 2 A18, A18 Firmware 2025-04-09 N/A 8.8 HIGH
Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
CVE-2024-35340 1 Tenda 2 Fh1206, Fh1206 Firmware 2025-04-09 N/A 8.6 HIGH
Tenda FH1206 V1.2.0.8(8155) was discovered to contain a command injection vulnerability via the cmdinput parameter at ip/goform/formexeCommand.
CVE-2024-35339 1 Tenda 2 Fh1206, Fh1206 Firmware 2025-04-09 N/A 9.8 CRITICAL
Tenda FH1206 V1.2.0.8(8155) was discovered to contain a command injection vulnerability via the mac parameter at ip/goform/WriteFacMac.
CVE-2024-30645 1 Tenda 2 Ac15, Ac15 Firmware 2025-04-08 N/A 8.0 HIGH
Tenda AC15V1.0 V15.03.20_multi has a command injection vulnerability via the deviceName parameter.
CVE-2024-30613 1 Tenda 2 Ac15, Ac15 Firmware 2025-04-08 N/A 4.3 MEDIUM
Tenda AC15 v15.03.05.18 has a stack overflow vulnerability in the time parameter from the setSmartPowerManagement function.