Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 1390 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2025-8060 1 Tenda 2 Ac23, Ac23 Firmware 2025-08-01 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC23 16.03.07.52 and classified as critical. Affected by this vulnerability is the function sub_46C940 of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-8178 1 Tenda 2 Ac10, Ac10 Firmware 2025-08-01 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /goform/RequestsProcessLaid. The manipulation of the argument device1D leads to heap-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-29360 1 Tenda 2 Rx3, Rx3 Firmware 2025-08-01 N/A 7.5 HIGH
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the time and timeZone parameters at /goform/SetSysTimeCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29359 1 Tenda 2 Rx3, Rx3 Firmware 2025-08-01 N/A 7.5 HIGH
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the deviceId parameter at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29358 1 Tenda 2 Rx3, Rx3 Firmware 2025-08-01 N/A 7.5 HIGH
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the firewallEn parameter at /goform/SetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29357 1 Tenda 2 Rx3, Rx3 Firmware 2025-08-01 N/A 7.5 HIGH
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the startIp and endIp parameters at /goform/SetPptpServerCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-3820 1 Tenda 4 I24, I24 Firmware, W12 and 1 more 2025-07-30 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644) and classified as critical. Affected by this issue is the function cgiSysUplinkCheckSet of the file /bin/httpd. The manipulation of the argument hostIp1/hostIp2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-3802 1 Tenda 4 I24, I24 Firmware, W12 and 1 more 2025-07-30 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). It has been declared as critical. This vulnerability affects the function cgiPingSet of the file /bin/httpd. The manipulation of the argument pingIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-3803 1 Tenda 4 I24, I24 Firmware, W12 and 1 more 2025-07-30 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). It has been rated as critical. This issue affects the function cgiSysScheduleRebootSet of the file /bin/httpd. The manipulation of the argument rebootDate leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-4007 1 Tenda 4 I24, I24 Firmware, W12 and 1 more 2025-07-30 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). Affected by this vulnerability is the function cgidhcpsCfgSet of the file /goform/modules of the component httpd. The manipulation of the argument json leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-51089 1 Tenda 2 Ac8, Ac8 Firmware 2025-07-28 N/A 6.5 MEDIUM
Tenda AC8V4 V16.03.34.06` was discovered to contain heap overflow at /goform/GetParentControlInfo.The manipulation of the argument `mac` leads to heap-based buffer overflow.
CVE-2025-51088 1 Tenda 2 Ac8, Ac8 Firmware 2025-07-28 N/A 5.3 MEDIUM
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/WifiGuestSet. The manipulation of the argument `shareSpeed` leads to stack-based buffer overflow.
CVE-2025-51087 1 Tenda 2 Ac8, Ac8 Firmware 2025-07-28 N/A 8.6 HIGH
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow.
CVE-2025-51085 1 Tenda 2 Ac8, Ac8 Firmware 2025-07-28 N/A 5.3 MEDIUM
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argument `timeZone` and `timeType` leads to stack-based buffer overflow.
CVE-2025-51082 1 Tenda 2 Ac8, Ac8 Firmware 2025-07-28 N/A 5.3 MEDIUM
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/fast_setting_wifi_set. The manipulation of the argument `timeZone` leads to stack-based buffer overflow.
CVE-2025-7807 1 Tenda 2 Fh451, Fh451 Firmware 2025-07-23 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda FH451 1.0.0.9. This issue affects the function fromSafeUrlFilter of the file /goform/SafeUrlFilter. The manipulation of the argument Go/page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7806 1 Tenda 2 Fh451, Fh451 Firmware 2025-07-23 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. This vulnerability affects the function fromSafeClientFilter of the file /goform/SafeClientFilter. The manipulation of the argument Go/page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7805 1 Tenda 2 Fh451, Fh451 Firmware 2025-07-23 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7796 1 Tenda 2 Fh451, Fh451 Firmware 2025-07-23 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, was found in Tenda FH451 1.0.0.9. This affects the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument Username leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7795 1 Tenda 2 Fh451, Fh451 Firmware 2025-07-23 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda FH451 1.0.0.9. Affected by this issue is the function fromP2pListFilter of the file /goform/P2pListFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.