CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2017-6867 | 1 Siemens | 3 Simatic Wincc, Simatic Wincc \(tia Portal\), Simatic Wincc Runtime | 2025-04-20 | 4.0 MEDIUM | 4.9 MEDIUM |
A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface. | |||||
CVE-2017-2680 | 1 Siemens | 183 S110 Pn, Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware and 180 more | 2025-04-20 | 6.1 MEDIUM | 6.5 MEDIUM |
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. | |||||
CVE-2017-2685 | 1 Siemens | 3 Sinumerik Integrate Access Mymachine\/ethernet, Sinumerik Integrate Operate Client, Sinumerik Operate | 2025-04-20 | 5.8 MEDIUM | 7.4 HIGH |
Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack. | |||||
CVE-2017-6865 | 1 Siemens | 16 Pcs 7, Primary Setup Tool, Security Configuration Tool and 13 more | 2025-04-20 | 6.1 MEDIUM | 6.5 MEDIUM |
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover. | |||||
CVE-2017-12737 | 1 Siemens | 2 Sm-2556, Sm-2556 Firmware | 2025-04-20 | 5.0 MEDIUM | 5.3 MEDIUM |
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the network. | |||||
CVE-2017-12735 | 1 Siemens | 2 Logo\!, Logo\! 8 Bm Firmware | 2025-04-20 | 5.8 MEDIUM | 7.4 HIGH |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. | |||||
CVE-2016-2518 | 7 Debian, Freebsd, Netapp and 4 more | 18 Debian Linux, Freebsd, Clustered Data Ontap and 15 more | 2025-04-20 | 5.0 MEDIUM | 5.3 MEDIUM |
The MATCH_ASSOC function in NTP before version 4.2.8p9 and 4.3.x before 4.3.92 allows remote attackers to cause an out-of-bounds reference via an addpeer request with a large hmode value. | |||||
CVE-2017-0144 | 2 Microsoft, Siemens | 27 Server Message Block, Windows 10 1507, Windows 10 1511 and 24 more | 2025-04-20 | 9.3 HIGH | 8.8 HIGH |
The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0143, CVE-2017-0145, CVE-2017-0146, and CVE-2017-0148. | |||||
CVE-2017-9940 | 1 Siemens | 1 Sipass Integrated | 2025-04-20 | 5.5 MEDIUM | 8.1 HIGH |
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with access to a low-privileged user account to read or write files on the file system of the SiPass integrated server over the network. | |||||
CVE-2017-2687 | 1 Siemens | 1 Ruggedcom Rox I | 2025-04-20 | 4.3 MEDIUM | 6.1 MEDIUM |
Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected Cross-Site Scripting attacks if an unsuspecting user is induced to click on a malicious link. | |||||
CVE-2017-2686 | 1 Siemens | 1 Ruggedcom Rox I | 2025-04-20 | 4.0 MEDIUM | 6.5 MEDIUM |
Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability that could allow an authenticated user to read arbitrary files through the web interface at port 10000/TCP and access sensitive information. | |||||
CVE-2017-12741 | 1 Siemens | 76 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200p and 73 more | 2025-04-20 | 7.8 HIGH | 7.5 HIGH |
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually. | |||||
CVE-2017-13099 | 3 Arubanetworks, Siemens, Wolfssl | 4 Instant, Scalance W1750d, Scalance W1750d Firmware and 1 more | 2025-04-20 | 4.3 MEDIUM | 7.5 HIGH |
wolfSSL prior to version 3.12.2 provides a weak Bleichenbacher oracle when any TLS cipher suite using RSA key exchange is negotiated. An attacker can recover the private key from a vulnerable wolfSSL application. This vulnerability is referred to as "ROBOT." | |||||
CVE-2017-12739 | 1 Siemens | 2 Sm-2556, Sm-2556 Firmware | 2025-04-20 | 10.0 HIGH | 9.8 CRITICAL |
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected device. | |||||
CVE-2017-14491 | 13 Arista, Arubanetworks, Canonical and 10 more | 29 Eos, Arubaos, Ubuntu Linux and 26 more | 2025-04-20 | 7.5 HIGH | 9.8 CRITICAL |
Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execute arbitrary code via a crafted DNS response. | |||||
CVE-2017-0143 | 3 Microsoft, Philips, Siemens | 28 Server Message Block, Windows 10 1507, Windows 10 1511 and 25 more | 2025-04-20 | 9.3 HIGH | 8.8 HIGH |
The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0144, CVE-2017-0145, CVE-2017-0146, and CVE-2017-0148. | |||||
CVE-2017-6866 | 1 Siemens | 1 Xhq Server | 2025-04-20 | 4.0 MEDIUM | 6.5 MEDIUM |
A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level. | |||||
CVE-2017-5711 | 3 Asus, Intel, Siemens | 394 B150-a, B150-a Firmware, B150-plus and 391 more | 2025-04-20 | 7.2 HIGH | 7.8 HIGH |
Multiple buffer overflows in Active Management Technology (AMT) in Intel Manageability Engine Firmware 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20 allow attacker with local access to the system to execute arbitrary code with AMT execution privilege. | |||||
CVE-2017-9941 | 1 Siemens | 1 Sipass Integrated | 2025-04-20 | 5.8 MEDIUM | 7.4 HIGH |
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication. | |||||
CVE-2017-6870 | 1 Siemens | 1 Simatic Wincc Sm\@rtclient | 2025-04-20 | 5.8 MEDIUM | 7.4 HIGH |
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack. |