Filtered by vendor Siemens
Subscribe
Total
2107 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2011-4515 | 1 Siemens | 1 Wincc Tia Portal | 2025-04-11 | 4.6 MEDIUM | N/A |
| Siemens WinCC (TIA Portal) 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging (1) physical access or (2) Sm@rt Server access. | |||||
| CVE-2013-2780 | 1 Siemens | 18 Simatic S7-1200, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1211c Firmware and 15 more | 2025-04-11 | 7.8 HIGH | N/A |
| Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port). | |||||
| CVE-2013-3959 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-11 | 4.0 MEDIUM | N/A |
| The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters. | |||||
| CVE-2013-0669 | 1 Siemens | 1 Wincc Tia Portal | 2025-04-11 | 4.0 MEDIUM | N/A |
| The HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to cause a denial of service (daemon crash) via a crafted HTTP request. | |||||
| CVE-2014-1696 | 1 Siemens | 1 Simatic Wincc Open Architecture | 2025-04-11 | 5.0 MEDIUM | N/A |
| Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack. | |||||
| CVE-2011-4511 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2025-04-11 | 4.3 MEDIUM | N/A |
| Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510. | |||||
| CVE-2013-0670 | 1 Siemens | 1 Wincc Tia Portal | 2025-04-11 | 4.3 MEDIUM | N/A |
| CRLF injection vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL. | |||||
| CVE-2013-0674 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-11 | 6.8 MEDIUM | N/A |
| Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter. | |||||
| CVE-2012-3028 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-11 | 6.8 MEDIUM | N/A |
| Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service. | |||||
| CVE-2012-4691 | 1 Siemens | 1 Automation License Manager | 2025-04-11 | 3.3 LOW | N/A |
| Memory leak in Siemens Automation License Manager (ALM) 4.x and 5.x before 5.2 allows remote attackers to cause a denial of service (memory consumption) via crafted packets. | |||||
| CVE-2013-5944 | 1 Siemens | 3 Scalance X-200, Scalance X-200 Series Firmware, Scalance X-200irt | 2025-04-11 | 10.0 HIGH | N/A |
| The integrated web server on Siemens SCALANCE X-200 switches with firmware before 4.5.0 and X-200IRT switches with firmware before 5.1.0 does not properly enforce authentication requirements, which allows remote attackers to perform administrative actions via requests to the management interface. | |||||
| CVE-2013-0668 | 1 Siemens | 1 Wincc Tia Portal | 2025-04-11 | 4.3 MEDIUM | N/A |
| Multiple cross-site scripting (XSS) vulnerabilities in the HMI web application in Siemens WinCC (TIA Portal) 11 allow remote attackers to inject arbitrary web script or HTML via a crafted URL. | |||||
| CVE-2013-5709 | 1 Siemens | 9 Scalance X-200, Scalance X-200 Series Firmware, Scalance X-200rna and 6 more | 2025-04-11 | 8.3 HIGH | N/A |
| The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value. | |||||
| CVE-2013-6920 | 1 Siemens | 14 Sinamics G110, Sinamics G110d, Sinamics G120 and 11 more | 2025-04-11 | 10.0 HIGH | N/A |
| Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23. | |||||
| CVE-2011-4530 | 1 Siemens | 1 Automation License Manager | 2025-04-11 | 5.0 MEDIUM | N/A |
| Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 does not properly copy fields obtained from clients, which allows remote attackers to cause a denial of service (exception and daemon crash) via long fields, as demonstrated by fields to the (1) open_session->workstation->NAME or (2) grant->VERSION function. | |||||
| CVE-2012-2441 | 1 Siemens | 1 Ruggedcom Rugged Operating System | 2025-04-11 | 8.5 HIGH | N/A |
| RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803. | |||||
| CVE-2011-4055 | 1 Siemens | 1 Tecnomatix Factorylink | 2025-04-11 | 9.3 HIGH | N/A |
| Buffer overflow in the WebClient ActiveX control in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to execute arbitrary code via a long string in a parameter associated with the location URL. | |||||
| CVE-2013-4781 | 1 Siemens | 2 Enterprise Openscape Branch, Openscape Session Border Controller | 2025-04-11 | 10.0 HIGH | N/A |
| core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to execute arbitrary commands via unspecified vectors. | |||||
| CVE-2011-4056 | 1 Siemens | 1 Tecnomatix Factorylink | 2025-04-11 | 5.8 MEDIUM | N/A |
| An unspecified ActiveX control in ActBar.ocx in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to create or overwrite arbitrary files via the save method. | |||||
| CVE-2011-4876 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2025-04-11 | 9.3 HIGH | N/A |
| Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string. | |||||