Vulnerabilities (CVE)

Filtered by vendor Medtronic Subscribe
Total 25 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2018-10634 1 Medtronic 18 Minimed 530g Mmt-551, Minimed 530g Mmt-551 Firmware, Minimed 530g Mmt-751 and 15 more 2024-11-21 2.9 LOW 5.3 MEDIUM
Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G communications between the pump and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.
CVE-2018-10631 1 Medtronic 4 N\'vision 8840, N\'vision 8840 Firmware, N\'vision 8870 and 1 more 2024-11-21 4.6 MEDIUM 6.6 MEDIUM
Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programmer, all versions, and 8870 N'Vision removable Application Card, all versions. The 8840 Clinician Programmer executes the application program from the 8870 Application Card. An attacker with physical access to an 8870 Application Card and sufficient technical capability can modify the contents of this card, including the binary executables. If modified to bypass protection mechanisms, this malicious code will be run when the card is inserted into an 8840 Clinician Programmer.
CVE-2018-10626 1 Medtronic 4 Mycarelink 24950 Patient Monitor, Mycarelink 24950 Patient Monitor Firmware, Mycarelink 24952 Patient Monitor and 1 more 2024-11-21 3.8 LOW 4.4 MEDIUM
A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected product's update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.
CVE-2018-10622 1 Medtronic 4 Mycarelink 24950 Patient Monitor, Mycarelink 24950 Patient Monitor Firmware, Mycarelink 24952 Patient Monitor and 1 more 2024-11-21 1.9 LOW 7.1 HIGH
A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected products use per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication and encryption of local data at rest.
CVE-2018-10596 1 Medtronic 2 2090 Carelink Programmer, 2090 Carelink Programmer Firmware 2024-11-21 5.2 MEDIUM 8.0 HIGH
Medtronic 2090 CareLink Programmer all versions The affected product uses a virtual private network connection to securely download updates. The product does not verify it is still connected to this virtual private network before downloading updates. An attacker with local network access to the programmer could influence these communications.