Vulnerabilities (CVE)

Filtered by vendor Belden Subscribe
Total 30 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2019-12259 4 Belden, Siemens, Sonicwall and 1 more 49 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 46 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and vx7 has an array index error in the IGMPv3 client component. There is an IPNET security vulnerability: DoS via NULL dereference in IGMP parsing.
CVE-2019-12258 5 Belden, Netapp, Siemens and 2 more 50 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 47 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
Wind River VxWorks 6.6 through vx7 has Session Fixation in the TCP component. This is a IPNET security vulnerability: DoS of TCP connection via malformed TCP options.
CVE-2019-12257 5 Belden, Netapp, Siemens and 2 more 46 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 43 more 2024-11-21 5.8 MEDIUM 8.8 HIGH
Wind River VxWorks 6.6 through 6.9 has a Buffer Overflow in the DHCP client component. There is an IPNET security vulnerability: Heap overflow in DHCP Offer/ACK parsing inside ipdhcpc.
CVE-2019-12256 5 Belden, Netapp, Siemens and 2 more 50 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 47 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets’ IP options.
CVE-2019-12255 5 Belden, Netapp, Siemens and 2 more 50 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 47 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
Wind River VxWorks has a Buffer Overflow in the TCP component (issue 1 of 4). This is a IPNET security vulnerability: TCP Urgent Pointer = 0 that leads to an integer underflow.
CVE-2018-5471 1 Belden 134 Hirschmann M1-8mm-sc, Hirschmann M1-8sfp, Hirschmann M1-8sm-sc and 131 more 2024-11-21 4.3 MEDIUM 5.9 MEDIUM
A Cleartext Transmission of Sensitive Information issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A cleartext transmission of sensitive information vulnerability in the web interface has been identified, which may allow an attacker to obtain sensitive information through a successful man-in-the-middle attack.
CVE-2018-5469 1 Belden 134 Hirschmann M1-8mm-sc, Hirschmann M1-8sfp, Hirschmann M1-8sm-sc and 131 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An improper restriction of excessive authentication vulnerability in the web interface has been identified, which may allow an attacker to brute force authentication.
CVE-2018-5467 1 Belden 134 Hirschmann M1-8mm-sc, Hirschmann M1-8sfp, Hirschmann M1-8sm-sc and 131 more 2024-11-21 6.4 MEDIUM 6.5 MEDIUM
An Information Exposure Through Query Strings in GET Request issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An information exposure through query strings vulnerability in the web interface has been identified, which may allow an attacker to impersonate a legitimate user.
CVE-2018-5465 1 Belden 134 Hirschmann M1-8mm-sc, Hirschmann M1-8sfp, Hirschmann M1-8sm-sc and 131 more 2024-11-21 6.8 MEDIUM 8.8 HIGH
A Session Fixation issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A session fixation vulnerability in the web interface has been identified, which may allow an attacker to hijack web sessions.
CVE-2018-5461 1 Belden 134 Hirschmann M1-8mm-sc, Hirschmann M1-8sfp, Hirschmann M1-8sm-sc and 131 more 2024-11-21 5.8 MEDIUM 6.5 MEDIUM
An Inadequate Encryption Strength issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An inadequate encryption strength vulnerability in the web interface has been identified, which may allow an attacker to obtain sensitive information through a successful man-in-the-middle attack.