Filtered by vendor Schneider-electric
Subscribe
Filtered by product Modicon M340 Bmxp341000 Firmware
Subscribe
Total
27 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2019-6855 | 1 Schneider-electric | 44 Ecostruxure Control Expert, Modicon M340 Bmxp341000, Modicon M340 Bmxp341000 Firmware and 41 more | 2024-11-21 | 7.5 HIGH | 7.3 HIGH |
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers. | |||||
CVE-2018-7762 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow. | |||||
CVE-2018-7761 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution. | |||||
CVE-2018-7760 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization. | |||||
CVE-2018-7759 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied. | |||||
CVE-2018-7242 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | 5.0 MEDIUM | 9.8 CRITICAL |
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks. | |||||
CVE-2018-7241 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. |