CVE-2016-7114 | 1 Siemens | 2 En100 Ethernet Module, En100 Ethernet Module Firmware | 2025-04-12 | 9.0 HIGH | 8.8 HIGH |
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.87; SIPROTEC 7UT686 : All versions < V 4.02; SIPROTEC 7SD686 : All versions < V 4.05; SIPROTEC 7SJ66 : All versions < V 4.30. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful. | |||||
CVE-2014-2252 | 1 Siemens | 6 Simatic S7 Cpu-1211c, Simatic S7 Cpu 1200 Firmware, Simatic S7 Cpu 1212c and 3 more | 2025-04-12 | 6.1 MEDIUM | N/A |
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted PROFINET packets, a different vulnerability than CVE-2014-2253. | |||||
CVE-2015-1598 | 1 Siemens | 1 Spcanywhere | 2025-04-12 | 2.1 LOW | N/A |
The Siemens SPCanywhere application for Android does not properly store application passwords, which allows physically proximate attackers to obtain sensitive information by examining the device filesystem. | |||||
CVE-2014-4685 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-12 | 4.6 MEDIUM | N/A |
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control. | |||||
CVE-2012-4693 | 2 Invensys, Siemens | 2 Wonderware Intouch, Processsuite | 2025-04-11 | 1.9 LOW | N/A |
Invensys Wonderware InTouch 2012 R2 and earlier and Siemens ProcessSuite use a weak encryption algorithm for data in Ps_security.ini, which makes it easier for local users to discover passwords by reading this file. | |||||
CVE-2013-4943 | 1 Siemens | 1 Comos | 2025-04-11 | 7.2 HIGH | N/A |
The client application in Siemens COMOS before 9.1 Update 458, 9.2 before 9.2.0.6.37, and 10.0 before 10.0.3.0.19 allows local users to gain privileges and bypass intended database-operation restrictions by leveraging COMOS project access. | |||||
CVE-2013-3634 | 1 Siemens | 7 Scalance X200-4p Irt, Scalance X200irt Firmware, Scalance X201-3p Irt and 4 more | 2025-04-11 | 7.5 HIGH | N/A |
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials. | |||||
CVE-2012-3009 | 1 Siemens | 1 Comos | 2025-04-11 | 8.5 HIGH | N/A |
Siemens COMOS before 9.1 Patch 413, 9.2 before Update 03 Patch 023, and 10.0 before Patch 005 allows remote authenticated users to obtain database administrative access via unspecified method calls. | |||||
CVE-2013-0675 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-11 | 6.1 MEDIUM | N/A |
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet. | |||||
CVE-2012-3003 | 1 Siemens | 1 Wincc | 2025-04-11 | 5.8 MEDIUM | N/A |
Open redirect vulnerability in an unspecified web application in Siemens WinCC 7.0 SP3 before Update 2 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in a GET request. | |||||
CVE-2013-4652 | 1 Siemens | 17 Scalance W700 Series Firmware, Scalance W744-1, Scalance W744-1pro and 14 more | 2025-04-11 | 10.0 HIGH | N/A |
Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection. | |||||
CVE-2013-3927 | 1 Siemens | 1 Comos | 2025-04-11 | 4.6 MEDIUM | N/A |
Unspecified vulnerability in the client library in Siemens COMOS 9.2 before 9.2.0.6.10 and 10.0 before 10.0.3.0.4 allows local users to obtain unintended write access to the database by leveraging read access. | |||||
CVE-2012-4698 | 1 Siemens | 4 Ros, Rox I Os, Rox Ii Os and 1 more | 2025-04-11 | 4.3 MEDIUM | N/A |
Siemens RuggedCom Rugged Operating System (ROS) before 3.12, ROX I OS through 1.14.5, ROX II OS through 2.3.0, and RuggedMax OS through 4.2.1.4621.22 use hardcoded private keys for SSL and SSH communication, which makes it easier for man-in-the-middle attackers to spoof servers and decrypt network traffic by leveraging the availability of these keys within ROS files at all customer installations. | |||||
CVE-2013-4779 | 1 Siemens | 2 Enterprise Openscape Branch, Openscape Session Border Controller | 2025-04-11 | 4.3 MEDIUM | N/A |
Cross-site scripting (XSS) vulnerability in core/handleTw.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
CVE-2012-5409 | 1 Siemens | 1 Sipass Integrated | 2025-04-11 | 10.0 HIGH | N/A |
AscoServer.exe in the server in Siemens SiPass integrated MP2.6 and earlier does not properly handle IOCP RPC messages received over an Ethernet network, which allows remote attackers to write data to any memory location and consequently execute arbitrary code via crafted messages, as demonstrated by an arbitrary pointer dereference attack or a buffer overflow attack. | |||||
CVE-2014-1697 | 1 Siemens | 1 Simatic Wincc Open Architecture | 2025-04-11 | 7.5 HIGH | N/A |
The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999. | |||||
CVE-2013-0659 | 1 Siemens | 4 Cp 1604, Cp 1604 Firmware, Cp 1616 and 1 more | 2025-04-11 | 10.0 HIGH | N/A |
The debugging feature on the Siemens CP 1604 and CP 1616 interface cards with firmware before 2.5.2 allows remote attackers to execute arbitrary code via a crafted packet to UDP port 17185. | |||||
CVE-2011-4514 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2025-04-11 | 10.0 HIGH | N/A |
The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session. | |||||
CVE-2012-3015 | 1 Siemens | 2 Simatic Pcs7, Simatic Step 7 | 2025-04-11 | 6.9 MEDIUM | N/A |
Untrusted search path vulnerability in Siemens SIMATIC STEP7 before 5.5 SP1, as used in SIMATIC PCS7 7.1 SP3 and earlier and other products, allows local users to gain privileges via a Trojan horse DLL in a STEP7 project folder. | |||||
CVE-2011-4508 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2025-04-11 | 9.3 HIGH | N/A |
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie. |