Vulnerabilities (CVE)

Total 306126 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2025-52392 2025-08-19 N/A 5.4 MEDIUM
Soosyze CMS 2.0 allows brute-force login attacks via the /user/login endpoint due to missing rate-limiting and lockout mechanisms. An attacker can repeatedly submit login attempts without restrictions, potentially gaining unauthorized administrative access. This vulnerability corresponds to CWE-307: Improper Restriction of Excessive Authentication Attempts.
CVE-2025-51510 2025-08-19 N/A 4.9 MEDIUM
MoonShine v3.12.5 was discovered to contain a SQL injection vulnerability via the Data parameter under the Blog module.
CVE-2025-43738 2025-08-19 N/A N/A
A reflected cross-site scripting (XSS) vulnerability in the Liferay Portal 7.4.0 through 7.4.3.132, and Liferay DXP 2025.Q2.0 through 2025.Q2.8, 2025.Q1.0 through 2025.Q1.15, 2024.Q4.0 through 2024.Q4.7, 2024.Q3.1 through 2024.Q3.13, 2024.Q2.1 through 2024.Q2.13 and 2024.Q1.1 through 2024.Q1.19 allows a remote authenticated user to inject JavaScript code via _com_liferay_expando_web_portlet_ExpandoPortlet_displayType parameter.
CVE-2025-2634 1 Ni 1 Labview 2025-08-19 N/A 7.8 HIGH
Out of bounds read vulnerability due to improper bounds checking in NI LabVIEW in fontmgr may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
CVE-2025-2633 1 Ni 1 Labview 2025-08-19 N/A 7.8 HIGH
Out of bounds read vulnerability due to improper bounds checking in NI LabVIEW in lvre!UDecStrToNum that may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
CVE-2024-22315 1 Ibm 3 Storage Fusion, Storage Fusion Hci, Storage Fusion Hci For Watsonx 2025-08-19 N/A 4.0 MEDIUM
IBM Fusion and IBM Fusion HCI 2.3.0 through 2.8.2 is vulnerable to insecure network connection by allowing an attacker who gains access to a Fusion container to establish an external network connection.
CVE-2025-7849 1 Ni 1 Labview 2025-08-19 N/A 7.8 HIGH
A memory corruption vulnerability due to improper error handling when a VILinkObj is null exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
CVE-2025-51501 1 Microweber 1 Microweber 2025-08-19 N/A 6.1 MEDIUM
Reflected Cross-Site Scripting (XSS) in the id parameter of the live_edit.module_settings API endpoint in Microweber CMS2.0 allows execution of arbitrary JavaScript.
CVE-2025-51502 1 Microweber 1 Microweber 2025-08-19 N/A 6.1 MEDIUM
Reflected Cross-Site Scripting (XSS) in Microweber CMS 2.0 via the layout parameter on the /admin/page/create page allows arbitrary JavaScript execution in the context of authenticated admin users.
CVE-2025-51504 1 Microweber 1 Microweber 2025-08-19 N/A 7.6 HIGH
Microweber CMS 2.0 is vulnerable to Cross Site Scripting (XSS)in the /projects/profile, homepage endpoint via the last name field.
CVE-2025-32829 1 Siemens 1 Telecontrol Server Basic 2025-08-19 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32830 1 Siemens 1 Telecontrol Server Basic 2025-08-19 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32831 1 Siemens 1 Telecontrol Server Basic 2025-08-19 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32832 1 Siemens 1 Telecontrol Server Basic 2025-08-19 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32833 1 Siemens 1 Telecontrol Server Basic 2025-08-19 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32834 1 Siemens 1 Telecontrol Server Basic 2025-08-19 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariablesWithImport' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32835 1 Siemens 1 Telecontrol Server Basic 2025-08-19 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariableArchivingBuffering' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32836 1 Siemens 1 Telecontrol Server Basic 2025-08-19 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32837 1 Siemens 1 Telecontrol Server Basic 2025-08-19 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32838 1 Siemens 1 Telecontrol Server Basic 2025-08-19 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.