Vulnerabilities (CVE)

Filtered by CWE-787
Total 12513 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-29524 1 Fujielectric 1 V-server 2024-11-21 6.8 MEDIUM 7.8 HIGH
Out-of-bounds write vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file.
CVE-2022-29496 1 Blynk 1 Blynk-library 2024-11-21 7.5 HIGH 9.8 CRITICAL
A stack-based buffer overflow vulnerability exists in the BlynkConsole.h runCommand functionality of Blynk -Library v1.0.1. A specially-crafted network request can lead to command execution. An attacker can send a network request to trigger this vulnerability.
CVE-2022-29465 1 Accusoft 1 Imagegear 2024-11-21 N/A 9.8 CRITICAL
An out-of-bounds write vulnerability exists in the PSD Header processing memory allocation functionality of Accusoft ImageGear 20.0. A specially-crafted malformed file can lead to memory corruption. An attacker can provide a malicious file to trigger this vulnerability.
CVE-2022-29399 1 Totolink 2 N600r, N600r Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
TOTOLINK N600R V4.3.0cu.7647_B20210106 was discovered to contain a stack overflow via the url parameter in the function FUN_00415bf0.
CVE-2022-29398 1 Totolink 2 N600r, N600r Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
TOTOLINK N600R V4.3.0cu.7647_B20210106 was discovered to contain a stack overflow via the File parameter in the function FUN_0041309c.
CVE-2022-29397 1 Totolink 2 N600r, N600r Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
TOTOLINK N600R V4.3.0cu.7647_B20210106 was discovered to contain a stack overflow via the comment parameter in the function FUN_004196c8.
CVE-2022-29396 1 Totolink 2 N600r, N600r Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
TOTOLINK N600R V4.3.0cu.7647_B20210106 was discovered to contain a stack overflow via the comment parameter in the function FUN_00418f10.
CVE-2022-29395 1 Totolink 2 N600r, N600r Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
TOTOLINK N600R V4.3.0cu.7647_B20210106 was discovered to contain a stack overflow via the apcliKey parameter in the function FUN_0041bac4.
CVE-2022-29394 1 Totolink 2 N600r, N600r Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
TOTOLINK N600R V4.3.0cu.7647_B20210106 was discovered to contain a stack overflow via the macAddress parameter in the function FUN_0041b448.
CVE-2022-29393 1 Totolink 2 N600r, N600r Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
TOTOLINK N600R V4.3.0cu.7647_B20210106 was discovered to contain a stack overflow via the comment parameter in the function FUN_004192cc.
CVE-2022-29392 1 Totolink 2 N600r, N600r Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
TOTOLINK N600R V4.3.0cu.7647_B20210106 was discovered to contain a stack overflow via the comment parameter in the function FUN_00418c24.
CVE-2022-29391 1 Totolink 2 N600r, N600r Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
TOTOLINK N600R V4.3.0cu.7647_B20210106 was discovered to contain a stack overflow via the comment parameter in the function FUN_004200c8.
CVE-2022-29379 1 F5 1 Njs 2024-11-21 7.5 HIGH 9.8 CRITICAL
Nginx NJS v0.7.3 was discovered to contain a stack overflow in the function njs_default_module_loader at /src/njs/src/njs_module.c. NOTE: multiple third parties dispute this report, e.g., the behavior is only found in unreleased development code that was not part of the 0.7.2, 0.7.3, or 0.7.4 release
CVE-2022-29377 1 Totolink 2 A3600r, A3600r Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
Totolink A3600R V4.1.2cu.5182_B20201102 was discovered to contain a stacker overflow in the fread function at infostat.cgi. This vulnerability allows attackers to cause a Denial of Service (DoS) via the parameter CONTENT_LENGTH.
CVE-2022-29329 1 Dlink 2 Dap-1330, Dap-1330 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
D-Link DAP-1330_OSS-firmware_1.00b21 was discovered to contain a heap overflow via the devicename parameter in /goform/setDeviceSettings.
CVE-2022-29328 1 Dlink 2 Dap-1330, Dap-1330 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
D-Link DAP-1330_OSS-firmware_1.00b21 was discovered to contain a stack overflow via the function checkvalidupgrade.
CVE-2022-29327 1 Dlink 2 Dir-816, Dir-816 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
D-Link DIR-816 A2_v1.10CNB04 was discovered to contain a stack overflow via the urladd parameter in /goform/websURLFilterAddDel.
CVE-2022-29326 1 Dlink 2 Dir-816, Dir-816 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
D-Link DIR-816 A2_v1.10CNB04 was discovered to contain a stack overflow via the addhostfilter parameter in /goform/websHostFilter.
CVE-2022-29325 1 Dlink 2 Dir-816, Dir-816 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
D-Link DIR-816 A2_v1.10CNB04 was discovered to contain a stack overflow via the addurlfilter parameter in /goform/websURLFilter.
CVE-2022-29324 1 Dlink 2 Dir-816, Dir-816 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
D-Link DIR-816 A2_v1.10CNB04 was discovered to contain a stack overflow via the proto parameter in /goform/form2IPQoSTcAdd.