Vulnerabilities (CVE)

Filtered by CWE-78
Total 4312 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2019-1726 1 Cisco 29 Mds 9000, Mds 9100, Mds 9200 and 26 more 2024-11-21 4.6 MEDIUM 7.8 HIGH
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to access internal services that should be restricted on an affected device, such as the NX-API. The vulnerability is due to insufficient validation of arguments passed to a certain CLI command. An attacker could exploit this vulnerability by including malicious input as the argument to the affected command. A successful exploit could allow the attacker to bypass intended restrictions and access internal services of the device. An attacker would need valid device credentials to exploit this vulnerability.
CVE-2019-1725 1 Cisco 1 Unified Computing System 2024-11-21 3.6 LOW 5.5 MEDIUM
A vulnerability in the local management CLI implementation for specific commands on the Cisco UCS B-Series Blade Servers could allow an authenticated, local attacker to overwrite an arbitrary file on disk. It is also possible the attacker could inject CLI command parameters that should not be allowed for a specific subset of local management CLI commands. The vulnerability is due to lack of proper input validation of user input for local management CLI commands. An attacker could exploit this vulnerability by authenticating to the device and issuing a crafted form of a limited subset of local management CLI commands. An exploit could allow the attacker to overwrite an arbitrary files on disk or inject CLI command parameters that should have been disabled. This vulnerability is fixed in software version 4.0(2a) and later.
CVE-2019-1674 2 Cisco, Microsoft 4 Webex Meetings, Webex Meetings Online, Webex Productivity Tools and 1 more 2024-11-21 9.0 HIGH 7.8 HIGH
A vulnerability in the update service of Cisco Webex Meetings Desktop App and Cisco Webex Productivity Tools for Windows could allow an authenticated, local attacker to execute arbitrary commands as a privileged user. The vulnerability is due to insufficient validation of user-supplied parameters. An attacker could exploit this vulnerability by invoking the update service command with a crafted argument. An exploit could allow the attacker to run arbitrary commands with SYSTEM user privileges. While the CVSS Attack Vector metric denotes the requirement for an attacker to have local access, administrators should be aware that in Active Directory deployments, the vulnerability could be exploited remotely by leveraging the operating system remote management tools. This vulnerability is fixed in Cisco Webex Meetings Desktop App Release 33.6.6 and 33.9.1 releases. This vulnerability is fixed in Cisco Webex Productivity Tools Release 33.0.7.
CVE-2019-1650 1 Cisco 12 Sd-wan, Vbond Orchestrator, Vedge 100 and 9 more 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability in the Cisco SD-WAN Solution could allow an authenticated, remote attacker to overwrite arbitrary files on the underlying operating system of an affected device. The vulnerability is due to improper input validation of the save command in the CLI of the affected software. An attacker could exploit this vulnerability by modifying the save command in the CLI of an affected device. A successful exploit could allow the attacker to overwrite arbitrary files on the underlying operating system of an affected device and escalate their privileges to the root user.
CVE-2019-1636 1 Cisco 1 Webex Teams 2024-11-21 9.3 HIGH 7.8 HIGH
A vulnerability in the Cisco Webex Teams client, formerly Cisco Spark, could allow an attacker to execute arbitrary commands on a targeted system. This vulnerability is due to unsafe search paths used by the application URI that is defined in Windows operating systems. An attacker could exploit this vulnerability by convincing a targeted user to follow a malicious link. Successful exploitation could cause the application to load libraries from the directory targeted by the URI link. The attacker could use this behavior to execute arbitrary commands on the system with the privileges of the targeted user if the attacker can place a crafted library in a directory that is accessible to the vulnerable system.
CVE-2019-1634 1 Cisco 13 Encs 5100, Encs 5400, Integrated Management Controller Supervisor and 10 more 2024-11-21 9.0 HIGH 7.2 HIGH
A vulnerability in the Intelligent Platform Management Interface (IPMI) of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker to inject arbitrary commands that are executed with root privileges on the underlying operating system (OS). The vulnerability is due to insufficient input validation of user-supplied commands. An attacker who has administrator privileges and access to the network where the IPMI resides could exploit this vulnerability by submitting crafted input to the affected commands. A successful exploit could allow the attacker to gain root privileges on the affected device.
CVE-2019-1627 1 Cisco 2 Integrated Management Controller, Unified Computing System 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
A vulnerability in the Server Utilities of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker to gain unauthorized access to sensitive user information from the configuration data that is stored on the affected system. The vulnerability is due to insufficient protection of data in the configuration file. An attacker could exploit this vulnerability by downloading the configuration file. An exploit could allow the attacker to use the sensitive information from the file to elevate privileges.
CVE-2019-1623 1 Cisco 1 Meeting Server 2024-11-21 7.2 HIGH 6.7 MEDIUM
A vulnerability in the CLI configuration shell of Cisco Meeting Server could allow an authenticated, local attacker to inject arbitrary commands as the root user. The vulnerability is due to insufficient input validation during the execution of a vulnerable CLI command. An attacker with administrator-level credentials could exploit this vulnerability by injecting crafted arguments during command execution. A successful exploit could allow the attacker to perform arbitrary code execution as root on an affected product.
CVE-2019-1614 1 Cisco 11 Mds 9000, Nexus 2000, Nexus 3000 and 8 more 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability in the NX-API feature of Cisco NX-OS Software could allow an authenticated, remote attacker to execute arbitrary commands with root privileges. The vulnerability is due to incorrect input validation of user-supplied data by the NX-API subsystem. An attacker could exploit this vulnerability by sending malicious HTTP or HTTPS packets to the management interface of an affected system that has the NX-API feature enabled. A successful exploit could allow the attacker to perform a command-injection attack and execute arbitrary commands with root privileges. Note: NX-API is disabled by default. MDS 9000 Series Multilayer Switches are affected running software versions prior to 8.1(1b) and 8.2(3). Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 2000, 5500, 5600, and 6000 Series Switches are affected running software versions prior to 7.3(4)N1(1). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 7000 and 7700 Series Switches are affected running software versions prior to 7.3(3)D1(1) and 8.2(3).
CVE-2019-1612 1 Cisco 6 Nexus 3000, Nexus 3500, Nexus 3600 and 3 more 2024-11-21 7.2 HIGH 4.2 MEDIUM
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5).
CVE-2019-1591 1 Cisco 2 Nexus 9000, Nx-os 2024-11-21 7.2 HIGH 7.8 HIGH
A vulnerability in a specific CLI command implementation of Cisco Nexus 9000 Series ACI Mode Switch Software could allow an authenticated, local attacker to escape a restricted shell on an affected device. The vulnerability is due to insufficient sanitization of user-supplied input when issuing a specific CLI command with parameters on an affected device. An attacker could exploit this vulnerability by authenticating to the device CLI and issuing certain commands. A successful exploit could allow the attacker to escape the restricted shell and execute arbitrary commands with root-level privileges on the affected device. This vulnerability only affects Cisco Nexus 9000 Series ACI Mode Switches that are running a release prior to 14.0(3d).
CVE-2019-1581 1 Paloaltonetworks 1 Pan-os 2024-11-21 7.5 HIGH 9.8 CRITICAL
A remote code execution vulnerability in the PAN-OS SSH device management interface that can lead to unauthenticated remote users with network access to the SSH management interface gaining root access to PAN-OS. This issue affects PAN-OS 7.1 versions prior to 7.1.24-h1, 7.1.25; 8.0 versions prior to 8.0.19-h1, 8.0.20; 8.1 versions prior to 8.1.9-h4, 8.1.10; 9.0 versions prior to 9.0.3-h3, 9.0.4.
CVE-2019-1576 1 Paloaltonetworks 1 Pan-os 2024-11-21 6.5 MEDIUM 8.8 HIGH
Command injection in PAN-0S 9.0.2 and earlier may allow an authenticated attacker to gain access to a remote shell in PAN-OS, and potentially run with the escalated user’s permissions.
CVE-2019-19994 1 Seling 1 Visual Access Manager 2024-11-21 10.0 HIGH 9.8 CRITICAL
An issue was discovered in Selesta Visual Access Manager (VAM) 4.15.0 through 4.29. It allows blind Command Injection. An attacker without authentication is able to execute arbitrary operating system command by injecting the vulnerable parameter in the PHP Web page /common/vam_monitor_sap.php.
CVE-2019-19940 1 Swisscom 2 Centro Grande, Centro Grande Firmware 2024-11-21 9.0 HIGH 7.2 HIGH
Incorrect input sanitation in text-oriented user interfaces (telnet, ssh) in Swisscom Centro Grande before 6.16.12 allows remote authenticated users to execute arbitrary commands via command injection.
CVE-2019-19920 3 Canonical, Debian, Sa-exim Project 3 Ubuntu Linux, Debian Linux, Sa-exim 2024-11-21 9.0 HIGH 8.8 HIGH
sa-exim 4.2.1 allows attackers to execute arbitrary code if they can write a .cf file or a rule. This occurs because Greylisting.pm relies on eval (rather than direct parsing and/or use of the taint feature). This issue is similar to CVE-2018-11805.
CVE-2019-19897 1 Ixpdata 1 Easyinstall 2024-11-21 10.0 HIGH 9.8 CRITICAL
In IXP EasyInstall 6.2.13723, there is Remote Code Execution via the Agent Service. An unauthenticated attacker can communicate with the Agent Service over TCP port 20051, and execute code in the NT AUTHORITY\SYSTEM context of the target system by using the Execute Command Line function.
CVE-2019-19842 1 Ruckuswireless 17 C110, E510, H320 and 14 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
emfd in Ruckus Wireless Unleashed through 200.7.10.102.64 allows remote attackers to execute OS commands via a POST request with the attribute xcmd=spectra-analysis to admin/_cmdstat.jsp via the mac attribute.
CVE-2019-19841 1 Ruckuswireless 17 C110, E510, H320 and 14 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
emfd in Ruckus Wireless Unleashed through 200.7.10.102.64 allows remote attackers to execute OS commands via a POST request with the attribute xcmd=packet-capture to admin/_cmdstat.jsp via the mac attribute.
CVE-2019-19839 1 Ruckuswireless 17 C110, E510, H320 and 14 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
emfd in Ruckus Wireless Unleashed through 200.7.10.102.64 allows remote attackers to execute OS commands via a POST request with the attribute xcmd=import-category to admin/_cmdstat.jsp via the uploadFile attribute.