Vulnerabilities (CVE)

Filtered by CWE-77
Total 2296 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2025-1616 2025-02-24 5.8 MEDIUM 4.7 MEDIUM
A vulnerability, which was classified as critical, has been found in FiberHome AN5506-01A ONU GPON RP2511. Affected by this issue is some unknown functionality of the component Diagnosis. The manipulation of the argument Destination Address leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-1610 2025-02-24 6.5 MEDIUM 6.3 MEDIUM
A vulnerability was found in LB-LINK AC1900 Router 1.0.2 and classified as critical. Affected by this issue is the function websGetVar of the file /goform/set_blacklist. The manipulation of the argument mac/enable leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-1609 2025-02-24 6.5 MEDIUM 6.3 MEDIUM
A vulnerability has been found in LB-LINK AC1900 Router 1.0.2 and classified as critical. Affected by this vulnerability is the function websGetVar of the file /goform/set_cmd. The manipulation of the argument cmd leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-1608 2025-02-24 6.5 MEDIUM 6.3 MEDIUM
A vulnerability, which was classified as critical, was found in LB-LINK AC1900 Router 1.0.2. Affected is the function websGetVar of the file /goform/set_manpwd. The manipulation of the argument routepwd  leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-1546 2025-02-21 7.5 HIGH 7.3 HIGH
A vulnerability has been found in BDCOM Behavior Management and Auditing System up to 20250210 and classified as critical. Affected by this vulnerability is the function log_operate_clear of the file /webui/modules/log/operate.mds. The manipulation of the argument start_code leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-1536 2025-02-21 7.5 HIGH 7.3 HIGH
A vulnerability was found in Raisecom Multi-Service Intelligent Gateway up to 20250208. It has been declared as critical. This vulnerability affects unknown code of the file /vpn/vpn_template_style.php of the component Request Parameter Handler. The manipulation of the argument stylenum leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-23149 1 Dek-1705 Project 2 Dek-1705, Dek-1705 Firmware 2025-02-20 N/A 9.8 CRITICAL
DEK-1705 <=Firmware:34.23.1 device was discovered to have a command execution vulnerability.
CVE-2025-0868 2025-02-20 N/A N/A
A vulnerability, that could result in Remote Code Execution (RCE), has been found in DocsGPT. Due to improper parsing of JSON data using eval() an unauthorized attacker could send arbitrary Python code to be executed via /api/remote endpoint. This issue affects DocsGPT: from 0.8.1 through 0.12.0.
CVE-2025-1448 2025-02-19 7.5 HIGH 7.3 HIGH
A vulnerability was found in Synway SMG Gateway Management Software up to 20250204. It has been rated as critical. This issue affects some unknown processing of the file 9-12ping.php. The manipulation of the argument retry leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-27232 1 Totolink 2 A7100ru, A7100ru Firmware 2025-02-18 N/A 9.8 CRITICAL
TOTOlink A7100RU V7.4cu.2313_B20191024 was discovered to contain a command injection vulnerability via the wanStrategy parameter at /setting/setWanIeCfg.
CVE-2023-27231 1 Totolink 2 A7100ru, A7100ru Firmware 2025-02-18 N/A 9.8 CRITICAL
TOTOlink A7100RU V7.4cu.2313_B20191024 was discovered to contain a command injection vulnerability via the downBw parameter at /setting/setWanIeCfg.
CVE-2023-27229 1 Totolink 2 A7100ru, A7100ru Firmware 2025-02-18 N/A 9.8 CRITICAL
TOTOlink A7100RU V7.4cu.2313_B20191024 was discovered to contain a command injection vulnerability via the upBw parameter at /setting/setWanIeCfg.
CVE-2025-1370 2025-02-18 4.3 MEDIUM 5.3 MEDIUM
A vulnerability, which was classified as critical, has been found in MicroWorld eScan Antivirus 7.0.32 on Linux. Affected by this issue is the function sprintf of the file epsdaemon of the component Autoscan USB. The manipulation leads to os command injection. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-1369 2025-02-18 3.5 LOW 4.5 MEDIUM
A vulnerability classified as critical was found in MicroWord eScan Antivirus 7.0.32 on Linux. Affected by this vulnerability is an unknown functionality of the component USB Password Handler. The manipulation leads to os command injection. The attack needs to be approached locally. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-5878 2025-02-18 N/A N/A
Honeywell OneWireless Wireless Device Manager (WDM) for the following versions R310.x, R320.x, R321.x, R322.1, R322.2, R323.x, R330.1 contains a command injection vulnerability. An attacker who is authenticated could use the firmware update process to potentially exploit the vulnerability, leading to a command injection. Honeywell recommends updating to R322.3, R330.2 or the most recent version of this product2.
CVE-2024-12356 1 Beyondtrust 2 Privileged Remote Access, Remote Support 2025-02-17 N/A 9.8 CRITICAL
A critical vulnerability has been discovered in Privileged Remote Access (PRA) and Remote Support (RS) products which can allow an unauthenticated attacker to inject commands that are run as a site user.
CVE-2025-1339 2025-02-16 6.5 MEDIUM 6.3 MEDIUM
A vulnerability was found in TOTOLINK X18 9.1.0cu.2024_B20220329. It has been rated as critical. This issue affects the function setL2tpdConfig of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument enable leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-1338 2025-02-16 7.5 HIGH 7.3 HIGH
A vulnerability was found in NUUO Camera up to 20250203. It has been declared as critical. This vulnerability affects the function print_file of the file /handle_config.php. The manipulation of the argument log leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-5461 2025-02-15 N/A N/A
Implementation of the Simple Network Management Protocol (SNMP) operating on the Brocade 6547 (FC5022) embedded switch blade, makes internal script calls to system.sh from within the SNMP binary. An authenticated attacker could perform command or parameter injection on SNMP operations that are only enabled on the Brocade 6547 (FC5022) embedded switch. This injection could allow the authenticated attacker to issue commands as Root.
CVE-2025-0593 2025-02-14 N/A 8.8 HIGH
The vulnerability may allow a remote low priviledged attacker to run arbitrary shell commands by using lower-level functions to interact with the device.