Total
110 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2019-13945 | 1 Siemens | 32 S7-200 Smart, S7-200 Smart Firmware, Simatic S7-1200 and 29 more | 2024-11-21 | 4.6 MEDIUM | 6.8 MEDIUM |
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process. | |||||
CVE-2019-12948 | 1 Polycom | 54 C12, C16, C8 and 51 more | 2024-11-21 | 6.5 MEDIUM | 8.3 HIGH |
A vulnerability in the web-based management interface of VVX, Trio, SoundStructure, SoundPoint, and SoundStation phones running Polycom UC Software, if exploited, could allow an authenticated, remote attacker with admin privileges to cause a denial of service (DoS) condition or execute arbitrary code. | |||||
CVE-2019-10918 | 1 Siemens | 4 Simatic Pcs 7, Simatic Wincc, Simatic Wincc \(tia Portal\) and 1 more | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
CVE-2018-8949 | 1 Misp-project | 1 Misp | 2024-11-21 | 5.5 MEDIUM | 4.3 MEDIUM |
An issue was discovered in app/Model/Attribute.php in MISP before 2.4.89. There is a critical API integrity bug, potentially allowing users to delete attributes of other events. A crafted edit for an event (without attribute UUIDs but attribute IDs set) could overwrite an existing attribute. | |||||
CVE-2018-8868 | 1 Medtronic | 4 24950 Mycarelink Monitor, 24950 Mycarelink Monitor Firmware, 24952 Mycarelink Monitor and 1 more | 2024-11-21 | 6.9 MEDIUM | 6.4 MEDIUM |
Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions, contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can apply the other vulnerabilities within this advisory to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality. | |||||
CVE-2018-10931 | 2 Cobbler Project, Redhat | 2 Cobbler, Satellite | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
It was found that cobbler 2.6.x exposed all functions from its CobblerXMLRPCInterface class over XMLRPC. A remote, unauthenticated attacker could use this flaw to gain high privileges within cobbler, upload files to arbitrary location in the context of the daemon. | |||||
CVE-2024-51992 | 2024-11-12 | N/A | 4.1 MEDIUM | ||
Orchid is a @laravel package that allows for rapid application development of back-office applications, admin/user panels, and dashboards. This vulnerability is a method exposure issue (CWE-749: Exposed Dangerous Method or Function) in the Orchid Platform’s asynchronous modal functionality, affecting users of Orchid Platform version 8 through 14.42.x. Attackers could exploit this vulnerability to call arbitrary methods within the `Screen` class, leading to potential brute force of database tables, validation checks against user credentials, and disclosure of the server’s real IP address. The issue has been patched in the latest release, version 14.43.0, released on November 6, 2024. Users should upgrade to version 14.43.0 or later to address this vulnerability. If upgrading to version 14.43.0 is not immediately possible, users can mitigate the vulnerability by implementing middleware to intercept and validate requests to asynchronous modal endpoints, allowing only approved methods and parameters. | |||||
CVE-2024-47005 | 2 Sharp, Toshibatec | 640 Bp-30c25, Bp-30c25 Firmware, Bp-30c25t and 637 more | 2024-11-05 | N/A | 8.1 HIGH |
Sharp and Toshiba Tec MFPs provide configuration related APIs. They are expected to be called by administrative users only, but insufficiently restricted. A non-administrative user may execute some configuration APIs. | |||||
CVE-2024-4739 | 1 Moxa | 1 Mxsecurity | 2024-10-22 | N/A | 5.3 MEDIUM |
The lack of access restriction to a resource from unauthorized users makes MXsecurity software versions v1.1.0 and prior vulnerable. By acquiring a valid authenticator, an attacker can pose as an authorized user and successfully access the resource. | |||||
CVE-2024-6510 | 1 Avg | 1 Internet Security | 2024-10-02 | N/A | 7.8 HIGH |
Local Privilege Escalation in AVG Internet Security v24 on Windows allows a local unprivileged user to escalate privileges to SYSTEM via COM-Hijacking. |