Total
153 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-34209 | 1 Easyuse | 1 Mailhunter Ultimate | 2024-11-21 | N/A | 5.0 MEDIUM |
Exposure of Sensitive System Information to an Unauthorized Control Sphere in create template function in EasyUse MailHunter Ultimate 2023 and earlier allow remote authenticated users to obtain the absolute path via unencrypted VIEWSTATE parameter. | |||||
CVE-2023-32550 | 1 Canonical | 1 Landscape | 2024-11-21 | N/A | 9.3 CRITICAL |
Landscape's server-status page exposed sensitive system information. This data leak included GET requests which contain information to attack and leak further information from the Landscape API. | |||||
CVE-2023-2541 | 1 Knime | 1 Business Hub | 2024-11-21 | N/A | 5.3 MEDIUM |
The Web Frontend of KNIME Business Hub before 1.4.0 allows an unauthenticated remote attacker to access internals about the application such as versions, host names, or IP addresses. No personal information or application data was exposed. | |||||
CVE-2023-20111 | 1 Cisco | 1 Identity Services Engine | 2024-11-21 | N/A | 6.5 MEDIUM |
A vulnerability in the web-based management interface of Cisco Identity Services Engine (ISE) could allow an authenticated, remote attacker to access sensitive information. This vulnerability is due to the improper storage of sensitive information within the web-based management interface. An attacker could exploit this vulnerability by logging in to the web-based management interface and viewing hidden fields within the application. A successful exploit could allow the attacker to access sensitive information, including device entry credentials, that could aid the attacker in further attacks. | |||||
CVE-2023-0342 | 1 Mongodb | 1 Ops Manager Server | 2024-11-21 | N/A | 3.1 LOW |
MongoDB Ops Manager Diagnostics Archive may not redact sensitive PEM key file password app settings. Archives do not include the PEM files themselves. This issue affects MongoDB Ops Manager v5.0 prior to 5.0.21 and MongoDB Ops Manager v6.0 prior to 6.0.12 | |||||
CVE-2023-0005 | 1 Paloaltonetworks | 1 Pan-os | 2024-11-21 | N/A | 4.1 MEDIUM |
A vulnerability in Palo Alto Networks PAN-OS software enables an authenticated administrator to expose the plaintext values of secrets stored in the device configuration and encrypted API keys. | |||||
CVE-2022-4968 | 1 Canonical | 1 Netplan | 2024-11-21 | N/A | 6.5 MEDIUM |
netplan leaks the private key of wireguard to local users. Versions after 1.0 are not affected. | |||||
CVE-2022-38710 | 2 Ibm, Microsoft | 4 Robotic Process Automation, Robotic Process Automation As A Service, Robotic Process Automation For Cloud Pak and 1 more | 2024-11-21 | N/A | 5.3 MEDIUM |
IBM Robotic Process Automation 21.0.1 and 21.0.2 could disclose sensitive version to an unauthorized control sphere information that could aid in further attacks against the system. IBM X-Force ID: 234292. | |||||
CVE-2022-34458 | 1 Dell | 3 Alienware Update, Command Update, Update | 2024-11-21 | N/A | 6.6 MEDIUM |
Dell Command | Update, Dell Update, and Alienware Update versions prior to 4.7 contain a Exposure of Sensitive System Information to an Unauthorized Control Sphere vulnerability in download operation component. A local malicious user could potentially exploit this vulnerability leading to the disclosure of confidential data. | |||||
CVE-2022-2403 | 1 Redhat | 1 Openshift | 2024-11-21 | N/A | 6.5 MEDIUM |
A credentials leak was found in the OpenShift Container Platform. The private key for the external cluster certificate was stored incorrectly in the oauth-serving-cert ConfigMaps, and accessible to any authenticated OpenShift user or service-account. A malicious user could exploit this flaw by reading the oauth-serving-cert ConfigMap in the openshift-config-managed namespace, compromising any web traffic secured using that certificate. | |||||
CVE-2022-28651 | 1 Jetbrains | 1 Intellij Idea | 2024-11-21 | 2.1 LOW | 8.4 HIGH |
In JetBrains IntelliJ IDEA before 2021.3.3 it was possible to get passwords from protected fields | |||||
CVE-2022-20734 | 1 Cisco | 1 Catalyst Sd-wan Manager | 2024-11-21 | 4.9 MEDIUM | 4.4 MEDIUM |
A vulnerability in Cisco SD-WAN vManage Software could allow an authenticated, local attacker to view sensitive information on an affected system. This vulnerability is due to insufficient file system restrictions. An authenticated attacker with netadmin privileges could exploit this vulnerability by accessing the vshell of an affected system. A successful exploit could allow the attacker to read sensitive information on the underlying operating system. | |||||
CVE-2022-20664 | 1 Cisco | 2 Email Security Appliance, Secure Email And Web Manager | 2024-11-21 | 3.5 LOW | 7.7 HIGH |
A vulnerability in the web management interface of Cisco Secure Email and Web Manager, formerly Cisco Security Management Appliance (SMA), and Cisco Email Security Appliance (ESA) could allow an authenticated, remote attacker to retrieve sensitive information from a Lightweight Directory Access Protocol (LDAP) external authentication server connected to an affected device. This vulnerability is due to a lack of proper input sanitization while querying the external authentication server. An attacker could exploit this vulnerability by sending a crafted query through an external authentication web page. A successful exploit could allow the attacker to gain access to sensitive information, including user credentials from the external authentication server. To exploit this vulnerability, an attacker would need valid operator-level (or higher) credentials. | |||||
CVE-2022-1902 | 1 Redhat | 1 Advanced Cluster Security | 2024-11-21 | N/A | 8.8 HIGH |
A flaw was found in the Red Hat Advanced Cluster Security for Kubernetes. Notifier secrets were not properly sanitized in the GraphQL API. This flaw allows authenticated ACS users to retrieve Notifiers from the GraphQL API, revealing secrets that can escalate their privileges. | |||||
CVE-2021-23135 | 1 Argoproj | 1 Argo Cd | 2024-11-21 | 2.1 LOW | 5.9 MEDIUM |
Exposure of System Data to an Unauthorized Control Sphere vulnerability in web UI of Argo CD allows attacker to cause leaked secret data into web UI error messages and logs. This issue affects Argo CD 1.8 versions prior to 1.8.7; 1.7 versions prior to 1.7.14. | |||||
CVE-2021-1544 | 1 Cisco | 1 Webex Meetings | 2024-11-21 | 2.1 LOW | 5.5 MEDIUM |
A vulnerability in logging mechanisms of Cisco Webex Meetings client software could allow an authenticated, local attacker to gain access to sensitive information. This vulnerability is due to unsafe logging of application actions. An attacker could exploit this vulnerability by logging onto the local system and accessing files containing the logged details. A successful exploit could allow the attacker to gain access to sensitive information, including meeting data and recorded meeting transcriptions. | |||||
CVE-2021-1535 | 1 Cisco | 1 Sd-wan Vmanage | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability in the cluster management interface of Cisco SD-WAN vManage Software could allow an unauthenticated, remote attacker to view sensitive information on an affected system. To be affected by this vulnerability, the Cisco SD-WAN vManage Software must be in cluster mode. This vulnerability is due to the absence of authentication for sensitive information in the cluster management interface. An attacker could exploit this vulnerability by sending a crafted request to the cluster management interface of an affected system. A successful exploit could allow the attacker to allow the attacker to view sensitive information on the affected system. | |||||
CVE-2021-1235 | 1 Cisco | 1 Sd-wan Vmanage | 2024-11-21 | 4.9 MEDIUM | 5.5 MEDIUM |
A vulnerability in the CLI of Cisco SD-WAN vManage Software could allow an authenticated, local attacker to read sensitive database files on an affected system. The vulnerability is due to insufficient user authorization. An attacker could exploit this vulnerability by accessing the vshell of an affected system. A successful exploit could allow the attacker to read database files from the filesystem of the underlying operating system. | |||||
CVE-2021-0291 | 1 Juniper | 2 Junos, Junos Os Evolved | 2024-11-21 | 6.4 MEDIUM | 6.5 MEDIUM |
An Exposure of System Data vulnerability in Juniper Networks Junos OS and Junos OS Evolved, where a sensitive system-level resource is not being sufficiently protected, allows a network-based unauthenticated attacker to send specific traffic which partially reaches this resource. A high rate of specific traffic may lead to a partial Denial of Service (DoS) as the CPU utilization of the RE is significantly increased. The SNMP Agent Extensibility (agentx) process should only be listening to TCP port 705 on the internal routing instance. External connections destined to port 705 should not be allowed. This issue affects: Juniper Networks Junos OS: 15.1 versions prior to 15.1R7-S9; 17.3 versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S8; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S2; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2; 20.3 versions prior to 20.3R2. Juniper Networks Junos OS Evolved versions prior to 20.3R2-EVO. This issue does not affect Juniper Networks Junos OS versions prior to 13.2R1. | |||||
CVE-2021-0260 | 1 Juniper | 1 Junos | 2024-11-21 | 7.5 HIGH | 7.3 HIGH |
An improper authorization vulnerability in the Simple Network Management Protocol daemon (snmpd) service of Juniper Networks Junos OS leads an unauthenticated attacker being able to perform SNMP read actions, an Exposure of System Data to an Unauthorized Control Sphere, or write actions to OIDs that support write operations, against the device without authentication. This issue affects: Juniper Networks Junos OS: 17.2 version 17.2R1 and later versions; 17.3 versions prior to 17.3R3-S9; 17.4 versions prior to 17.4R2-S12, 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R1-S8, 18.4R2-S5, 18.4R3; 19.1 versions prior to 19.1R2; 19.2 versions prior to 19.2R1-S6, 19.2R2; 19.3 versions prior to 19.3R2. This issue does not affect Juniper Networks Junos OS versions prior to 17.2R1. |