Vulnerabilities (CVE)

Filtered by CWE-310
Total 2484 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-41994 1 Pingidentity 2 Pingid, Pingid Windows Login 2024-11-21 1.9 LOW 6.6 MEDIUM
A misconfiguration of RSA in PingID iOS app prior to 1.19 is vulnerable to pre-computed dictionary attacks, leading to an offline MFA bypass when using PingID Windows Login.
CVE-2021-41993 1 Pingidentity 2 Pingid, Pingid Windows Login 2024-11-21 1.9 LOW 6.6 MEDIUM
A misconfiguration of RSA in PingID Android app prior to 1.19 is vulnerable to pre-computed dictionary attacks, leading to an offline MFA bypass when using PingID Windows Login.
CVE-2021-41992 1 Pingidentity 1 Pingid Integration For Windows Login 2024-11-21 1.9 LOW 7.7 HIGH
A misconfiguration of RSA in PingID Windows Login prior to 2.7 is vulnerable to pre-computed dictionary attacks, leading to an offline MFA bypass.
CVE-2021-22947 8 Apple, Debian, Fedoraproject and 5 more 34 Macos, Debian Linux, Fedora and 31 more 2024-11-21 4.3 MEDIUM 5.9 MEDIUM
When curl >= 7.20.0 and <= 7.78.0 connects to an IMAP or POP3 server to retrieve data using STARTTLS to upgrade to TLS security, the server can respond and send back multiple responses at once that curl caches. curl would then upgrade to TLS but not flush the in-queue of cached responses but instead continue using and trustingthe responses it got *before* the TLS handshake as if they were authenticated.Using this flaw, it allows a Man-In-The-Middle attacker to first inject the fake responses, then pass-through the TLS traffic from the legitimate server and trick curl into sending data back to the user thinking the attacker's injected data comes from the TLS-protected server.
CVE-2020-8897 1 Amazon 1 Aws Encryption Sdk 2024-11-21 5.5 MEDIUM 4.8 MEDIUM
A weak robustness vulnerability exists in the AWS Encryption SDKs for Java, Python, C and Javalcript prior to versions 2.0.0. Due to the non-committing property of AES-GCM (and other AEAD ciphers such as AES-GCM-SIV or (X)ChaCha20Poly1305) used by the SDKs to encrypt messages, an attacker can craft a unique cyphertext which will decrypt to multiple different results, and becomes especially relevant in a multi-recipient setting. We recommend users update their SDK to 2.0.0 or later.
CVE-2020-8173 1 Nextcloud 1 Nextcloud Server 2024-11-21 3.5 LOW 2.2 LOW
A too small set of random characters being used for encryption in Nextcloud Server 18.0.4 allowed decryption in shorter time than intended.
CVE-2020-8150 1 Nextcloud 1 Nextcloud Server 2024-11-21 1.9 LOW 4.1 MEDIUM
A cryptographic issue in Nextcloud Server 19.0.1 allowed an attacker to downgrade the encryption scheme and break the integrity of encrypted files.
CVE-2020-3389 1 Cisco 1 Hyperflex Hx-series Software 2024-11-21 2.1 LOW 4.4 MEDIUM
A vulnerability in the installation component of Cisco Hyperflex HX-Series Software could allow an authenticated, local attacker to retrieve the password that was configured at installation on an affected device. The vulnerability exists because sensitive information is stored as clear text. An attacker could exploit this vulnerability by authenticating to an affected device and navigating to the directory that contains sensitive information. A successful exploit could allow the attacker to obtain sensitive information in clear text from the affected device.
CVE-2019-9861 1 Abus 2 Secvest Wireless Alarm System Fuaa50000, Secvest Wireless Alarm System Fuaa50000 Firmware 2024-11-21 4.8 MEDIUM 8.1 HIGH
Due to the use of an insecure RFID technology (MIFARE Classic), ABUS proximity chip keys (RFID tokens) of the ABUS Secvest FUAA50000 wireless alarm system can easily be cloned and used to deactivate the alarm system in an unauthorized way.
CVE-2019-9506 8 Apple, Blackberry, Canonical and 5 more 274 Iphone Os, Mac Os X, Tvos and 271 more 2024-11-21 4.8 MEDIUM 8.1 HIGH
The Bluetooth BR/EDR specification up to and including version 5.1 permits sufficiently low encryption key length and does not prevent an attacker from influencing the key length negotiation. This allows practical brute-force attacks (aka "KNOB") that can decrypt traffic and inject arbitrary ciphertext without the victim noticing.
CVE-2019-9191 1 Etsi 1 Enterprise Transport Security 2024-11-21 4.3 MEDIUM 5.9 MEDIUM
The ETSI Enterprise Transport Security (ETS, formerly known as eTLS) protocol does not provide per-session forward secrecy.
CVE-2019-6576 1 Siemens 22 Simatic Hmi Comfort Outdoor Panels, Simatic Hmi Comfort Outdoor Panels Firmware, Simatic Hmi Comfort Panels and 19 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.
CVE-2019-3740 2 Dell, Oracle 18 Bsafe Cert-j, Bsafe Crypto-j, Bsafe Ssl-j and 15 more 2024-11-21 4.3 MEDIUM 6.5 MEDIUM
RSA BSAFE Crypto-J versions prior to 6.2.5 are vulnerable to an Information Exposure Through Timing Discrepancy vulnerabilities during DSA key generation. A malicious remote attacker could potentially exploit those vulnerabilities to recover DSA keys.
CVE-2019-3739 2 Dell, Oracle 16 Bsafe Cert-j, Bsafe Crypto-j, Bsafe Ssl-j and 13 more 2024-11-21 4.3 MEDIUM 6.5 MEDIUM
RSA BSAFE Crypto-J versions prior to 6.2.5 are vulnerable to Information Exposure Through Timing Discrepancy vulnerabilities during ECDSA key generation. A malicious remote attacker could potentially exploit those vulnerabilities to recover ECDSA keys.
CVE-2019-3731 1 Dell 2 Bsafe Crypto-c-micro-edition, Bsafe Micro-edition-suite 2024-11-21 5.0 MEDIUM 7.5 HIGH
RSA BSAFE Crypto-C Micro Edition versions prior to 4.1.4 and RSA Micro Edition Suite versions prior to 4.4 are vulnerable to an Information Exposure Through Timing Discrepancy. A malicious remote user could potentially exploit this vulnerability to extract information leaving data at risk of exposure.
CVE-2019-1940 1 Cisco 1 Industrial Network Director 2024-11-21 4.3 MEDIUM 5.9 MEDIUM
A vulnerability in the Web Services Management Agent (WSMA) feature of Cisco Industrial Network Director (IND) could allow an unauthenticated, remote attacker to gain unauthorized read access to sensitive data using an invalid X.509 certificate. The vulnerability is due to insufficient X.509 certificate validation when establishing a WSMA connection. An attacker could exploit this vulnerability by supplying a crafted X.509 certificate during the WSMA connection setup phase. A successful exploit could allow the attacker to conduct man-in-the-middle attacks to decrypt confidential information on WSMA connections to the affected software. At the time of publication, this vulnerability affected Cisco IND Software releases prior to 1.7.
CVE-2019-1804 1 Cisco 26 Nexus 93108tc-ex, Nexus 93108tc-ex Firmware, Nexus 93120tx and 23 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
A vulnerability in the SSH key management for the Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an unauthenticated, remote attacker to connect to the affected system with the privileges of the root user. The vulnerability is due to the presence of a default SSH key pair that is present in all devices. An attacker could exploit this vulnerability by opening an SSH connection via IPv6 to a targeted device using the extracted key materials. An exploit could allow the attacker to access the system with the privileges of the root user. This vulnerability is only exploitable over IPv6; IPv4 is not vulnerable.
CVE-2019-14261 1 Abus 2 Secvest Wireless Alarm System Fuaa50000, Secvest Wireless Alarm System Fuaa50000 Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
An issue was discovered on ABUS Secvest FUAA50000 3.01.01 devices. Due to an insufficient implementation of jamming detection, an attacker is able to suppress correctly received RF messages sent between wireless peripheral components, e.g., wireless detectors or remote controls, and the ABUS Secvest alarm central. An attacker is able to perform a "reactive jamming" attack. The reactive jamming simply detects the start of a RF message sent by a component of the ABUS Secvest wireless alarm system, for instance a wireless motion detector (FUBW50000) or a remote control (FUBE50014 or FUBE50015), and overlays it with random data before the original RF message ends. Thereby, the receiver (alarm central) is not able to properly decode the original transmitted signal. This enables an attacker to suppress correctly received RF messages of the wireless alarm system in an unauthorized manner, for instance status messages sent by a detector indicating an intrusion.
CVE-2019-10926 1 Siemens 4 Simatic Mv420, Simatic Mv420 Firmware, Simatic Mv440 and 1 more 2024-11-21 2.6 LOW 5.3 MEDIUM
A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). Communication with the device is not encrypted. Data transmitted between the device and the user can be obtained by an attacker in a privileged network position. The security vulnerability can be exploited by an attacker in a privileged network position which allows eavesdropping the communication between the affected device and the user. The user must invoke a session. Successful exploitation of the vulnerability compromises confidentiality of the data transmitted.
CVE-2018-7839 1 Schneider-electric 1 Iiot Monitor 2024-11-21 2.1 LOW 5.5 MEDIUM
A Cryptographic Issue (CWE-310) vulnerability exists in IIoT Monitor 3.1.38 which could allow information disclosure.