Vulnerabilities (CVE)

Filtered by CWE-284
Total 3294 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2019-7611 1 Elastic 1 Elasticsearch 2024-11-21 6.8 MEDIUM 8.1 HIGH
A permission issue was found in Elasticsearch versions before 5.6.15 and 6.6.1 when Field Level Security and Document Level Security are disabled and the _aliases, _shrink, or _split endpoints are used . If the elasticsearch.yml file has xpack.security.dls_fls.enabled set to false, certain permission checks are skipped when users perform one of the actions mentioned above, to make existing data available under a new index/alias name. This could result in an attacker gaining additional permissions against a restricted index.
CVE-2019-7476 1 Sonicwall 1 Global Management System 2024-11-21 6.8 MEDIUM 8.1 HIGH
A vulnerability in SonicWall Global Management System (GMS), allow a remote user to gain access to the appliance using existing SSH key. This vulnerability affects GMS versions 9.1, 9.0, 8.7, 8.6, 8.4, 8.3 and earlier.
CVE-2019-7475 1 Sonicwall 2 Sonicos, Sonicosv 2024-11-21 7.5 HIGH 9.8 CRITICAL
A vulnerability in SonicWall SonicOS and SonicOSv with management enabled system on specific configuration allow unprivileged user to access advanced routing services. This vulnerability affected SonicOS Gen 5 version 5.9.1.10 and earlier, Gen 6 version 6.2.7.3, 6.5.1.3, 6.5.2.2, 6.5.3.1, 6.2.7.8, 6.4.0.0, 6.5.1.8, 6.0.5.3-86o and SonicOSv 6.5.0.2-8v_RC363 (VMWARE), 6.5.0.2.8v_RC367 (AZURE), SonicOSv 6.5.0.2.8v_RC368 (AWS), SonicOSv 6.5.0.2.8v_RC366 (HYPER_V).
CVE-2019-6810 1 Schneider-electric 2 Bmxnor0200h, Bmxnor0200h Firmware 2024-11-21 6.5 MEDIUM 8.8 HIGH
CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol.
CVE-2019-6744 1 Samsung 2 Galaxy S9, Knox 2024-11-21 2.1 LOW 4.3 MEDIUM
This vulnerability allows local attackers to disclose sensitive information on affected installations of Samsung Knox 1.2.02.39 on Samsung Galaxy S9 build G9600ZHS3ARL1 Secure Folder. An attacker must first obtain physical access to the device in order to exploit this vulnerability. The specific flaws exists within the the handling of the lock screen for Secure Folder. The issue results from the lack of proper validation that a user has correctly authenticated. An attacker can leverage this vulnerability to disclose the contents of the secure container. Was ZDI-CAN-7381.
CVE-2019-6566 1 Ge 1 Ge Communicator 2024-11-21 7.2 HIGH 7.8 HIGH
GE Communicator, all versions prior to 4.0.517, allows a non-administrative user to replace the uninstaller with a malicious version, which could allow an attacker to gain administrator privileges to the system.
CVE-2019-6554 1 Advantech 1 Webaccess 2024-11-21 5.0 MEDIUM 7.5 HIGH
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. An improper access control vulnerability may allow an attacker to cause a denial-of-service condition.
CVE-2019-6544 1 Ge 1 Ge Communicator 2024-11-21 6.8 MEDIUM 5.6 MEDIUM
GE Communicator, all versions prior to 4.0.517, has a service running with system privileges that may allow an unprivileged user to perform certain administrative actions, which may allow the execution of scheduled scripts with system administrator privileges. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
CVE-2019-6538 1 Medtronic 40 Amplia Crt-d, Amplia Crt-d Firmware, Carelink 2090 and 37 more 2024-11-21 3.3 LOW 6.5 MEDIUM
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.
CVE-2019-6520 1 Moxa 8 Eds-405a, Eds-405a Firmware, Eds-408a and 5 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
Moxa IKS and EDS does not properly check authority on server side, which results in a read-only user being able to perform arbitrary configuration changes.
CVE-2019-6517 1 Bd 2 Facslyric, Facslyric Ivd 2024-11-21 4.6 MEDIUM 6.8 MEDIUM
BD FACSLyric Research Use Only, Windows 10 Professional Operating System, U.S. and Malaysian Releases, between November 2017 and November 2018 and BD FACSLyric IVD Windows 10 Professional Operating System US release does not properly enforce user access control to privileged accounts, which may allow for unauthorized access to administrative level functions.
CVE-2019-6193 1 Lenovo 1 Xclarity Administrator 2024-11-21 5.0 MEDIUM 7.5 HIGH
An information disclosure vulnerability was reported in Lenovo XClarity Administrator (LXCA) versions prior to 2.6.6 that could allow unauthenticated access to some configuration files which may contain usernames, license keys, IP addresses, and encrypted password hashes.
CVE-2019-6144 1 Forcepoint 1 One Endpoint 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
This vulnerability allows a normal (non-admin) user to disable the Forcepoint One Endpoint (versions 19.04 through 19.08) and bypass DLP and Web protection.
CVE-2019-6140 1 Forcepoint 1 Email Security 2024-11-21 7.5 HIGH 9.8 CRITICAL
A configuration issue has been discovered in Forcepoint Email Security 8.4.x and 8.5.x: the product is left in a vulnerable state if the hybrid registration process is not completed.
CVE-2019-5644 1 Gatech 1 Computing For Good\'s Basic Laboratory Information System 2024-11-21 7.5 HIGH 10.0 CRITICAL
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.
CVE-2019-5643 1 Gatech 1 Computing For Good\'s Basic Laboratory Information System 2024-11-21 5.0 MEDIUM 5.3 MEDIUM
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may enumerate the user names and facility names in use on a particular installation.
CVE-2019-5617 1 Gatech 1 Computing For Good\'s Basic Laboratory Information System 2024-11-21 7.5 HIGH 10.0 CRITICAL
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
CVE-2019-5487 1 Gitlab 1 Gitlab 2024-11-21 5.0 MEDIUM 5.3 MEDIUM
An improper access control vulnerability exists in Gitlab EE <v12.3.3, <v12.2.7, & <v12.1.13 that allowed the group search feature with Elasticsearch to return private code, merge requests and commits.
CVE-2019-5474 1 Gitlab 1 Gitlab 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
An authorization issue was discovered in GitLab EE < 12.1.2, < 12.0.4, and < 11.11.6 allowing the merge request approval rules to be overridden without appropriate permissions.
CVE-2019-5452 1 Nextcloud 1 Nextcloud 2024-11-21 2.1 LOW 2.4 LOW
Bypass lock protection in the Nextcloud Android app prior to version 3.6.2 causes leaking of thumbnails when requesting the Android content provider although the lock protection was not solved.