Export limit exceeded: 14270 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 19584 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (19584 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-50359 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 7.2 High |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "scan_ap" API which are not properly sanitized before being concatenated to OS level commands. | ||||
| CVE-2024-50360 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 7.2 High |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "snmp_apply" API which are not properly sanitized before being concatenated to OS level commands. | ||||
| CVE-2024-50361 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 7.2 High |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "certificate_file_remove" API which are not properly sanitized before being concatenated to OS level commands. | ||||
| CVE-2024-50362 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 7.2 High |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "connection_profile_apply" API which are not properly sanitized before being concatenated to OS level commands. | ||||
| CVE-2024-50363 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 7.2 High |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "mp_apply" API which are not properly sanitized before being concatenated to OS level commands. | ||||
| CVE-2024-50364 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 7.2 High |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "export_log" API which are not properly sanitized before being concatenated to OS level commands. | ||||
| CVE-2024-50365 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 7.2 High |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "lan_apply" API which are not properly sanitized before being concatenated to OS level commands. | ||||
| CVE-2024-22087 | 1 Alekseykurepin | 1 Pico Http Server In C | 2026-01-23 | 9.8 Critical |
| route in main.c in Pico HTTP Server in C through f3b69a6 has an sprintf stack-based buffer overflow via a long URI, leading to remote code execution. | ||||
| CVE-2024-50366 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 7.2 High |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "applications_apply" API which are not properly sanitized before being concatenated to OS level commands. | ||||
| CVE-2024-50367 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 7.2 High |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "sta_log_htm" API which are not properly sanitized before being concatenated to OS level commands. | ||||
| CVE-2024-50368 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 7.2 High |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands. | ||||
| CVE-2024-50369 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 7.2 High |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands. | ||||
| CVE-2024-50370 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 9.8 Critical |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation. | ||||
| CVE-2024-50371 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 9.8 Critical |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation. | ||||
| CVE-2024-50372 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 9.8 Critical |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation. | ||||
| CVE-2024-50373 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 9.8 Critical |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation. | ||||
| CVE-2024-50374 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 9.8 Critical |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation. | ||||
| CVE-2024-50375 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 9.8 Critical |
| A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point. | ||||
| CVE-2021-47772 | 1 10-strike | 1 Network Inventory Explorer | 2026-01-23 | 9.8 Critical |
| 10-Strike Network Inventory Explorer Pro 9.31 contains a buffer overflow vulnerability in the text file import functionality that allows remote code execution. Attackers can craft a malicious text file with carefully constructed payload to trigger a reverse shell and execute arbitrary code on the target system. | ||||
| CVE-2024-50376 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-01-23 | 7.3 High |
| A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID. | ||||