A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The impacted element is the function urlFilterManageRule of the file /goform/urlFilterManageRule. Executing manipulation of the argument urlFilterRuleName/scheduleUrl/addURLFilter can lead to stack-based buffer overflow. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.
Configurations

No configuration.

History

25 Aug 2025, 20:24

Type Values Removed Values Added
Summary
  • (es) Se ha detectado una falla en los Linksys RE6250, RE6300, RE6350, RE6500, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. El elemento afectado es la función urlFilterManageRule del archivo /goform/urlFilterManageRule. La manipulación del argumento urlFilterRuleName/scheduleUrl/addURLFilter puede provocar un desbordamiento del búfer basado en la pila. El ataque puede ejecutarse en remoto. Se contactó al proveedor con antelación para informarle sobre esta revelación, pero no respondió.

23 Aug 2025, 14:15

Type Values Removed Values Added
New CVE

Information

Published : 2025-08-23 14:15

Updated : 2025-08-25 20:24


NVD link : CVE-2025-9362

Mitre link : CVE-2025-9362

CVE.ORG link : CVE-2025-9362


JSON object : View

Products Affected

No product.

CWE
CWE-119

Improper Restriction of Operations within the Bounds of a Memory Buffer

CWE-121

Stack-based Buffer Overflow