A vulnerability was found in D-Link DI-8100 16.07.26A1. It has been classified as critical. This affects an unknown part of the file /menu_nat.asp of the component HTTP Request Handler. The manipulation of the argument out_addr/in_addr/out_port/proto leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:dlink:di-8100_firmware:16.07.26a1:*:*:*:*:*:*:*
cpe:2.3:h:dlink:di-8100:-:*:*:*:*:*:*:*

History

23 Jul 2025, 16:43

Type Values Removed Values Added
First Time Dlink
Dlink di-8100 Firmware
Dlink di-8100
CPE cpe:2.3:h:dlink:di-8100:-:*:*:*:*:*:*:*
cpe:2.3:o:dlink:di-8100_firmware:16.07.26a1:*:*:*:*:*:*:*
References () https://github.com/XiDP0/MyCVE/blob/main/CVE/D-Link%20DI_8100-16.07.26A1/menu_nat_asp/menu_nat_asp.md - () https://github.com/XiDP0/MyCVE/blob/main/CVE/D-Link%20DI_8100-16.07.26A1/menu_nat_asp/menu_nat_asp.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.316851 - () https://vuldb.com/?ctiid.316851 - Permissions Required
References () https://vuldb.com/?id.316851 - () https://vuldb.com/?id.316851 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.616196 - () https://vuldb.com/?submit.616196 - Third Party Advisory, VDB Entry
References () https://www.dlink.com/ - () https://www.dlink.com/ - Product

22 Jul 2025, 15:15

Type Values Removed Values Added
References () https://github.com/XiDP0/MyCVE/blob/main/CVE/D-Link%20DI_8100-16.07.26A1/menu_nat_asp/menu_nat_asp.md - () https://github.com/XiDP0/MyCVE/blob/main/CVE/D-Link%20DI_8100-16.07.26A1/menu_nat_asp/menu_nat_asp.md -

22 Jul 2025, 13:06

Type Values Removed Values Added
Summary
  • (es) Se encontró una vulnerabilidad en D-Link DI-8100 16.07.26A1. Se ha clasificado como crítica. Afecta una parte desconocida del archivo /menu_nat.asp del componente HTTP Request Handler. La manipulación del argumento out_addr/in_addr/out_port/proto provoca un desbordamiento del búfer basado en la pila. El ataque puede ejecutarse en remoto. Se ha hecho público el exploit y puede que sea utilizado.

18 Jul 2025, 16:15

Type Values Removed Values Added
New CVE

Information

Published : 2025-07-18 16:15

Updated : 2025-07-23 16:43


NVD link : CVE-2025-7790

Mitre link : CVE-2025-7790

CVE.ORG link : CVE-2025-7790


JSON object : View

Products Affected

dlink

  • di-8100
  • di-8100_firmware
CWE
CWE-119

Improper Restriction of Operations within the Bounds of a Memory Buffer

CWE-121

Stack-based Buffer Overflow