CVE-2024-31980

A vulnerability has been identified in Parasolid V35.1 (All versions < V35.1.256), Parasolid V36.0 (All versions < V36.0.210), Parasolid V36.1 (All versions < V36.1.185). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T part file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-23468)
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*

History

03 Oct 2025, 20:14

Type Values Removed Values Added
CPE cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*
First Time Siemens
Siemens parasolid
References () https://cert-portal.siemens.com/productcert/html/ssa-489698.html - () https://cert-portal.siemens.com/productcert/html/ssa-489698.html - Vendor Advisory

Information

Published : 2024-05-14 16:16

Updated : 2025-10-03 20:14


NVD link : CVE-2024-31980

Mitre link : CVE-2024-31980

CVE.ORG link : CVE-2024-31980


JSON object : View

Products Affected

siemens

  • parasolid
CWE
CWE-787

Out-of-bounds Write