This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the SrvrToSmSetAutoChnlListMsg function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root.
References
Configurations
No configuration.
History
31 Jan 2025, 20:15
Type | Values Removed | Values Added |
---|---|---|
CVSS |
v2 : v3 : |
v2 : unknown
v3 : 8.8 |
CWE | CWE-120 |
31 Jan 2025, 00:15
Type | Values Removed | Values Added |
---|---|---|
New CVE |
Information
Published : 2025-01-31 00:15
Updated : 2025-01-31 20:15
NVD link : CVE-2024-23968
Mitre link : CVE-2024-23968
CVE.ORG link : CVE-2024-23968
JSON object : View
Products Affected
No product.
CWE
CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')