CVE-2024-23143

A maliciously crafted 3DM, MODEL and X_B file, when parsed in ASMkern229A.dll and ASMBASE229A.dll through Autodesk applications, can force an Out-of-Bound Read and/or Out-of-Bound Write. A malicious actor can leverage this vulnerability to cause a crash,read sensitive data, or execute arbitrary code in the context of the current process.
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*

Configuration 2 (hide)

OR cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*

Configuration 3 (hide)

OR cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*

Configuration 4 (hide)

OR cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*

Configuration 5 (hide)

OR cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*

Configuration 6 (hide)

OR cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*

Configuration 7 (hide)

OR cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*

Configuration 8 (hide)

OR cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*

Configuration 9 (hide)

OR cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*

History

06 May 2025, 19:55

Type Values Removed Values Added
First Time Autodesk autocad Electrical
Autodesk autocad
Autodesk
Autodesk civil 3d
Autodesk autocad Architecture
Autodesk autocad Map 3d
Autodesk autocad Mechanical
Autodesk autocad Mep
Autodesk advance Steel
Autodesk autocad Plant 3d
CPE cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
References () https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0009 - () https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0009 - Vendor Advisory
CWE CWE-787

28 Jan 2025, 17:15

Type Values Removed Values Added
Summary (en) A maliciously crafted 3DM, MODEL and X_B file, when parsed in ASMkern229A.dll and ASMBASE229A.dll through Autodesk applications, can force an Out-of-Bound Read and/or Out-of-Bound Write. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process. (en) A maliciously crafted 3DM, MODEL and X_B file, when parsed in ASMkern229A.dll and ASMBASE229A.dll through Autodesk applications, can force an Out-of-Bound Read and/or Out-of-Bound Write. A malicious actor can leverage this vulnerability to cause a crash,read sensitive data, or execute arbitrary code in the context of the current process.
CVSS v2 : unknown
v3 : 8.8
v2 : unknown
v3 : 7.8
CWE CWE-787

Information

Published : 2024-06-25 02:15

Updated : 2025-05-06 19:55


NVD link : CVE-2024-23143

Mitre link : CVE-2024-23143

CVE.ORG link : CVE-2024-23143


JSON object : View

Products Affected

autodesk

  • autocad_map_3d
  • autocad_plant_3d
  • autocad_mep
  • autocad_architecture
  • autocad_mechanical
  • advance_steel
  • autocad
  • civil_3d
  • autocad_electrical
CWE
CWE-125

Out-of-bounds Read

CWE-787

Out-of-bounds Write