CVE-2024-11653

A vulnerability was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. It has been rated as critical. Affected by this issue is some unknown functionality of the file /admin/network/diag_traceroute. The manipulation of the argument diag_traceroute leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://k9u7kv33ub.feishu.cn/wiki/AHPnwdCaoiaQ3fkrdeUcqPfLnEd Exploit Third Party Advisory
https://vuldb.com/?ctiid.285974 Permissions Required VDB Entry
https://vuldb.com/?id.285974 Third Party Advisory VDB Entry
https://vuldb.com/?submit.446633 Third Party Advisory VDB Entry
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:engeniustech:enh1350ext_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:enh1350ext:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:engeniustech:ens620ext_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:ens620ext:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:engeniustech:ens500-ac_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:ens500-ac:-:*:*:*:*:*:*:*

History

12 Feb 2025, 15:33

Type Values Removed Values Added
CPE cpe:2.3:h:engeniustech:eens500-ac:-:*:*:*:*:*:*:* cpe:2.3:h:engeniustech:ens500-ac:-:*:*:*:*:*:*:*
First Time Engeniustech ens500-ac

10 Dec 2024, 23:13

Type Values Removed Values Added
First Time Engeniustech
Engeniustech ens620ext Firmware
Engeniustech eens500-ac
Engeniustech ens500-ac Firmware
Engeniustech enh1350ext
Engeniustech ens620ext
Engeniustech enh1350ext Firmware
References () https://k9u7kv33ub.feishu.cn/wiki/AHPnwdCaoiaQ3fkrdeUcqPfLnEd - () https://k9u7kv33ub.feishu.cn/wiki/AHPnwdCaoiaQ3fkrdeUcqPfLnEd - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.285974 - () https://vuldb.com/?ctiid.285974 - Permissions Required, VDB Entry
References () https://vuldb.com/?id.285974 - () https://vuldb.com/?id.285974 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.446633 - () https://vuldb.com/?submit.446633 - Third Party Advisory, VDB Entry
CPE cpe:2.3:o:engeniustech:ens620ext_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:ens620ext:-:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:enh1350ext_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:eens500-ac:-:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:enh1350ext:-:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:ens500-ac_firmware:*:*:*:*:*:*:*:*

Information

Published : 2024-11-25 04:15

Updated : 2025-02-12 15:33


NVD link : CVE-2024-11653

Mitre link : CVE-2024-11653

CVE.ORG link : CVE-2024-11653


JSON object : View

Products Affected

engeniustech

  • ens620ext
  • ens500-ac
  • ens620ext_firmware
  • enh1350ext_firmware
  • ens500-ac_firmware
  • enh1350ext
CWE
CWE-74

Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')

CWE-77

Improper Neutralization of Special Elements used in a Command ('Command Injection')