Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.
References
Link | Resource |
---|---|
https://jvn.jp/vu/JVNVU95103362 | Third Party Advisory |
https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 | Third Party Advisory US Government Resource |
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf | Vendor Advisory |
https://jvn.jp/vu/JVNVU95103362 | Third Party Advisory |
https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 | Third Party Advisory US Government Resource |
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf | Vendor Advisory |
Configurations
Configuration 1 (hide)
|
History
13 Feb 2025, 08:15
Type | Values Removed | Values Added |
---|---|---|
Summary | (en) Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products. |
16 Jan 2025, 05:15
Type | Values Removed | Values Added |
---|---|---|
Summary | (en) Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products. |
Information
Published : 2024-01-30 09:15
Updated : 2025-02-13 08:15
NVD link : CVE-2023-6943
Mitre link : CVE-2023-6943
CVE.ORG link : CVE-2023-6943
JSON object : View
Products Affected
mitsubishielectric
- fr_configurator2
- mc_works64
- gx_works3
- melsoft_navigator
- mt_works2
- mx_component
- ezsocket
- got1000
- got2000
- gx_works2
CWE
CWE-470