A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)
References
Link | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf | Vendor Advisory |
Configurations
History
No history.
Information
Published : 2023-10-10 11:15
Updated : 2024-11-21 08:08
NVD link : CVE-2023-35796
Mitre link : CVE-2023-35796
CVE.ORG link : CVE-2023-35796
JSON object : View
Products Affected
siemens
- sinema_server
CWE
CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')