Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface (/cgi/get_param.cgi) with the tmpToken cookie set to an empty string followed by a semicolon. This bypasses an active session authorization check. This can be then used to fetch the values of protected sys.passwd and sys.su.name fields that contain the username and password in cleartext.
                
            References
                    | Link | Resource | 
|---|---|
| https://gynvael.coldwind.pl/?lang=en&id=748 | Exploit Third Party Advisory | 
| https://gynvael.coldwind.pl/?lang=en&id=748 | Exploit Third Party Advisory | 
Configurations
                    Configuration 1 (hide)
| AND | 
            
            
 
  | 
    
Configuration 2 (hide)
| AND | 
            
            
 
  | 
    
Configuration 3 (hide)
| AND | 
            
            
 
  | 
    
Configuration 4 (hide)
| AND | 
            
            
 
  | 
    
Configuration 5 (hide)
| AND | 
            
            
 
  | 
    
Configuration 6 (hide)
| AND | 
            
            
 
  | 
    
Configuration 7 (hide)
| AND | 
            
            
 
  | 
    
History
                    No history.
Information
                Published : 2022-06-13 18:15
Updated : 2024-11-21 07:07
NVD link : CVE-2022-33174
Mitre link : CVE-2022-33174
CVE.ORG link : CVE-2022-33174
JSON object : View
Products Affected
                powertekpdus
- smart_pom
 - piml_pdu
 - smart_pim
 - smart_pos_firmware
 - smart_poms
 - smart_poms_firmware
 - pm_pdu
 - pm_pdu_firmware
 - smart_pim_firmware
 - basic_pdu
 - smart_pom_firmware
 - piml_pdu_firmware
 - smart_pos
 - basic_pdu_firmware
 
CWE
                
                    
                        
                        CWE-863
                        
            Incorrect Authorization