| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Due to a lack of standard encryption when transmitting sensitive information over the internet to a centralized monitoring service, the Eview EV-07S GPS Tracker discloses personally identifying information, such as GPS data and IMEI numbers, to any man-in-the-middle (MitM) listener. |
| An issue was discovered in sysPass 2.x before 2.1, in which an algorithm was never sufficiently reviewed by cryptographers. The fact that inc/SP/Core/Crypt.class is using the MCRYPT_RIJNDAEL_256() function (the 256-bit block version of Rijndael, not AES) instead of MCRYPT_RIJNDAEL_128 (real AES) could help an attacker to create unknown havoc in the remote system. |
| Apache OpenMeetings 1.0.0 uses not very strong cryptographic storage, captcha is not used in registration and forget password dialogs and auth forms missing brute force protection. |
| Dolibarr ERP/CRM 4.0.4 stores passwords with the MD5 algorithm, which makes brute-force attacks easier. |
| A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password. |
| A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands. |
| On the TP-Link TL-SG108E 1.0, admin network communications are RC4 encoded, even though RC4 is deprecated. This affects the 1.1.2 Build 20141017 Rel.50749 firmware. |
| Huawei USG6300 V100R001C30SPC300 and USG6600 with software of V100R001C30SPC500,V100R001C30SPC600,V100R001C30SPC700,V100R001C30SPC800 have a weak algorithm vulnerability. Attackers may exploit the weak algorithm vulnerability to crack the cipher text and cause confidential information leaks on the transmission links. |
| An Inadequate Encryption Strength issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). Decryption of data is possible at the hardware level. |
| The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user’s operating system and certain components of FactoryTalk View SE. |
| In specific scenarios, on Windows the operator credentials may be encrypted in a manner that is not completely machine-dependent.
|
| MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 uses the MD5 algorithm to hash the passwords before storing them but does not salt the hash. As a result, attackers may be able to crack the hashed passwords. |
| Inadequate encryption may allow the passwords for Emerson OpenEnterprise versions through 3.3.4 user accounts to be obtained. |
| An attacker could decipher the encryption and gain access to MDT AutoSave versions prior to v6.02.06. |
| Hills ComNav version 3002-19 suffers from a weak communication channel. Traffic across the local network for the configuration pages can be viewed by a malicious actor. The size of certain communications packets are predictable. This would allow an attacker to learn the state of the system if they can observe the traffic. This would be possible even if the traffic were encrypted, e.g., using WPA2, as the packet sizes would remain observable. The communication encryption scheme is theoretically sound, but is not strong enough for the level of protection required. |
| Inadequate encryption may allow the credentials used by Emerson OpenEnterprise, up through version 3.3.5, to access field devices and external systems to be obtained. |
| Passwords are not adequately encrypted during the communication process between all versions of LS Industrial Systems (LSIS) Co. Ltd LS Electric XG5000 software prior to V4.0 and LS Electric PLCs: all versions of XGK-CPUU/H/A/S/E prior to V3.50, all versions of XGI-CPUU/UD/H/S/E prior to V3.20, all versions of XGR-CPUH prior to V1.80, all versions of XGB-XBMS prior to V3.00, all versions of XGB-XBCH prior to V1.90, and all versions of XGB-XECH prior to V1.30. This would allow an attacker to identify and decrypt the password of the affected PLCs by sniffing the PLC’s communication traffic. |
| The Config-files of Horner Automation’s RCC 972 with firmware version 15.40 are encrypted with weak XOR encryption vulnerable to reverse engineering. This could allow an attacker to obtain credentials to run services such as File Transfer Protocol (FTP) and Hypertext Transfer Protocol (HTTP). |
| IO FinNet tss-lib before 2.0.0 allows a collision of hash values. |
| Huawei AR routers with software before V200R007C00SPC100; Quidway S9300 routers with software before V200R009C00; S12700 routers with software before V200R008C00SPC500; S9300, Quidway S5300, and S5300 routers with software before V200R007C00; and S5700 routers with software before V200R007C00SPC500 makes it easier for remote authenticated administrators to obtain encryption keys and ciphertext passwords via vectors related to key storage. |