Search Results (2199 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2020-25184 3 Rockwellautomation, Schneider-electric, Xylem 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more 2025-04-16 7.8 High
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
CVE-2022-3088 2 Debian, Moxa 129 Debian Linux, Aig-301-ap-azu-lx, Aig-301-ap-azu-lx Firmware and 126 more 2025-04-16 7.8 High
UC-8100A-ME-T System Image: Versions v1.0 to v1.6, UC-2100 System Image: Versions v1.0 to v1.12, UC-2100-W System Image: Versions v1.0 to v 1.12, UC-3100 System Image: Versions v1.0 to v1.6, UC-5100 System Image: Versions v1.0 to v1.4, UC-8100 System Image: Versions v3.0 to v3.5, UC-8100-ME-T System Image: Versions v3.0 and v3.1, UC-8200 System Image: v1.0 to v1.5, AIG-300 System Image: v1.0 to v1.4, UC-8410A with Debian 9 System Image: Versions v4.0.2 and v4.1.2, UC-8580 with Debian 9 System Image: Versions v2.0 and v2.1, UC-8540 with Debian 9 System Image: Versions v2.0 and v2.1, and DA-662C-16-LX (GLB) System Image: Versions v1.0.2 to v1.1.2 of Moxa's ARM-based computers have an execution with unnecessary privileges vulnerability, which could allow an attacker with user-level privileges to gain root privileges.
CVE-2021-23207 1 Fresenius-kabi 7 Agilia Connect, Agilia Partner Maintenance Software, Link\+ Agilia and 4 more 2025-04-16 6.5 Medium
An attacker with physical access to the host can extract the secrets from the registry and create valid JWT tokens for the Fresenius Kabi Vigilant MasterMed version 2.0.1.3 application and impersonate arbitrary users. An attacker could manipulate RabbitMQ queues and messages by impersonating users.
CVE-2021-32978 1 Automationdirect 40 C0-10are-d, C0-10are-d Firmware, C0-10dd1e-d and 37 more 2025-04-16 7.5 High
The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00.
CVE-2022-1517 1 Illumina 8 Iseq 100, Local Run Manager, Miniseq and 5 more 2025-04-16 10 Critical
LRM utilizes elevated privileges. An unauthenticated malicious actor can upload and execute code remotely at the operating system level, which can allow an attacker to change settings, configurations, software, or access sensitive data on the affected produc. An attacker could also exploit this vulnerability to access APIs not intended for general use and interact through the network.
CVE-2022-2634 1 Digi 2 Connectport X2d, Connectport X2d Firmware 2025-04-16 10 Critical
An attacker may be able to execute malicious actions due to the lack of device access protections and device permissions when using the web application. This could lead to uploading python files which can be later executed.
CVE-2022-41653 1 Daikinlatam 2 Svmpc1, Svmpc2 2025-04-16 9.8 Critical
Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system.
CVE-2021-40401 3 Debian, Fedoraproject, Gerbv Project 3 Debian Linux, Fedora, Gerbv 2025-04-15 8.6 High
A use-after-free vulnerability exists in the RS-274X aperture definition tokenization functionality of Gerbv 2.7.0 and dev (commit b5f1eacd) and Gerbv forked 2.7.1. A specially-crafted gerber file can lead to code execution. An attacker can provide a malicious file to trigger this vulnerability.
CVE-2022-27172 1 Inhandnetworks 2 Ir302, Ir302 Firmware 2025-04-15 8.8 High
A hard-coded password vulnerability exists in the console infactory functionality of InHand Networks InRouter302 V3.5.37. A specially-crafted network request can lead to privileged operation execution. An attacker can send a sequence of requests to trigger this vulnerability.
CVE-2022-22144 1 Tcl 1 Linkhub Mesh Wifi Ac1200 2025-04-15 9.8 Critical
A hard-coded password vulnerability exists in the libcommonprod.so prod_change_root_passwd functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. During system startup this functionality is always called, leading to a known root password. An attacker does not have to do anything to trigger this vulnerability.
CVE-2017-20039 1 Sicunet 1 Access Control 2025-04-15 9.8 Critical
A vulnerability was found in SICUNET Access Controller 0.32-05z. It has been classified as very critical. This affects an unknown part. The manipulation leads to weak authentication. It is possible to initiate the attack remotely.
CVE-2022-22458 2 Ibm, Linux 2 Security Verify Governance, Linux Kernel 2025-04-15 6.3 Medium
IBM Security Verify Governance, Identity Manager 10.0.1 stores user credentials in plain clear text which can be read by a remote authenticated user. IBM X-Force ID: 225009.
CVE-2022-3807 1 Axiosys 1 Bento4 2025-04-15 4.3 Medium
A vulnerability was found in Axiomatic Bento4. It has been rated as problematic. Affected by this issue is some unknown functionality of the component Incomplete Fix CVE-2019-13238. The manipulation leads to resource consumption. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-212660.
CVE-2023-41610 1 Govicture 2 Pc420, Pc420 Firmware 2025-04-14 8.8 High
Victure PC420 1.1.39 was discovered to contain a hardcoded root password which is stored in plaintext.
CVE-2014-6076 1 Ibm 2 Security Access Manager For Mobile, Security Access Manager For Web 2025-04-12 N/A
IBM Security Access Manager for Mobile 8.x before 8.0.1 and Security Access Manager for Web 7.x before 7.0.0 FP10 and 8.x before 8.0.1 allow remote attackers to conduct clickjacking attacks via a crafted web site.
CVE-2004-2777 1 Gehealthcare 1 Centricity Image Vault Firmware 2025-04-12 N/A
GE Healthcare Centricity Image Vault 3.x has a password of (1) gemnet for the administrator account, (2) webadmin for the webadmin administrator account of the ASACA DVD library, (3) an empty value for the gemsservice account of the Ultrasound Database, and possibly (4) gemnet2002 for the gemnet2002 account of the GEMNet license server, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
CVE-2010-5306 1 Gehealthcare 3 Optima Ct520 Firmware, Optima Ct540 Firmware, Optima Ct680 Firmware 2025-04-12 N/A
GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of #bigguy for the root user, which has unspecified impact and attack vectors.
CVE-2010-5307 1 Gehealthcare 1 Optima Mr360 Firmware 2025-04-12 N/A
The HIPAA configuration interface in GE Healthcare Optima MR360 has a password of (1) operator for the root account, (2) adw2.0 for the admin account, and (3) adw2.0 for the sdc account, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value.
CVE-2010-5308 1 Gehealthcare 1 Optima Mr360 Firmware 2025-04-12 N/A
GE Healthcare Optima MR360 does not require authentication for the HIPAA emergency login procedure, which allows physically proximate users to gain access via an arbitrary username in the Emergency Login screen. NOTE: this might not qualify for inclusion in CVE if unauthenticated emergency access is part of the intended security policy of the product, can be controlled by the system administrator, and is not enabled by default.
CVE-2010-5309 1 Gehealthcare 1 Cadstream Server Firmware 2025-04-12 N/A
GE Healthcare CADStream Server has a default password of confirma for the admin user, which has unspecified impact and attack vectors.