| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position. |
| An insufficient logging [CWE-778] vulnerability in FortiSandbox versions 4.0.0 to 4.0.2, 3.2.0 to 3.2.3 and 3.1.0 to 3.1.5 and FortiDeceptor versions 4.2.0, 4.1.0 through 4.1.1, 4.0.0 through 4.0.2, 3.3.0 through 3.3.3, 3.2.0 through 3.2.2,3.1.0 through 3.1.1 and 3.0.0 through 3.0.2 may allow a remote attacker to repeatedly enter incorrect credentials without causing a log entry, and with no limit on the number of failed authentication attempts. |
| The Motorola MOSCAD and ACE line of RTUs through 2022-05-02 omit an authentication requirement. They feature IP Gateway modules which allow for interfacing between Motorola Data Link Communication (MDLC) networks (potentially over a variety of serial, RF and/or Ethernet links) and TCP/IP networks. Communication with RTUs behind the gateway is done by means of the proprietary IPGW protocol (5001/TCP). This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality. |
| A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) |
| An attacker can freely brute force username and password and can takeover any account. An attacker could easily guess user passwords and gain access to user and administrative accounts. |
| Missing Critical Step in Authentication in GitHub repository namelessmc/nameless prior to v2.0.2. |
| Authentication Bypass by Primary Weakness in GitHub repository bookwyrm-social/bookwyrm prior to 0.4.5. |
| Improper Restriction of Excessive Authentication Attempts in GitHub repository heroiclabs/nakama prior to 3.13.0. This results in login brute-force attacks. |
| Multiple Lenze products of the cabinet series skip the password verification upon second login. After a user has been logged on to the device once, a remote attacker can get full access without knowledge of the password. |
| The KUKA SystemSoftware V/KSS in versions prior to 8.6.5 is prone to improper access control as an unauthorized attacker can directly read and write robot configurations when access control is not available or not enabled (default). |
| The Emerson DeltaV Distributed Control System (DCS) through 2022-04-29 mishandles authentication. It utilizes several proprietary protocols for a wide variety of functionality. These protocols include Firmware upgrade (18508/TCP, 18518/TCP); Plug-and-Play (18510/UDP); Hawk services (18507/UDP); Management (18519/TCP); Cold restart (18512/UDP); SIS communications (12345/TCP); and Wireless Gateway Protocol (18515/UDP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. |
| Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. |
| JTEKT TOYOPUC PLCs through 2022-04-29 mishandle authentication. They utilize the CMPLink/TCP protocol (configurable on ports 1024-65534 on either TCP or UDP) for a wide variety of engineering purposes such as starting and stopping the PLC, downloading and uploading projects, and changing configuration settings. This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality. |
| USU Oracle Optimization before 5.17.5 lacks Polkit authentication, which allows smartcollector users to achieve root access via pkexec. NOTE: this is not an Oracle Corporation product. |
| A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices allow unauthenticated access to the web interface configuration area. This could allow an attacker to extract internal configuration details or to reconfigure network settings. However, the reconfigured settings cannot be activated unless the role of an authenticated administrator user. |
| TP-Link TL-WR840N EU v6.20 was discovered to contain insecure protections for its UART console. This vulnerability allows attackers to connect to the UART port via a serial connection and execute commands as the root user without authentication. |
| In Nagios XI through 5.8.5, it is possible for a user without password verification to change his e-mail address. |
| Dell Unity, Dell UnityVSA, and Dell Unity XT versions before 5.2.0.0.5.173 do not restrict excessive authentication attempts in Unisphere GUI. A remote unauthenticated attacker may potentially exploit this vulnerability to brute-force passwords and gain access to the system as the victim. Account takeover is possible if weak passwords are used by users. |
| A improper restriction of excessive authentication attempts vulnerability [CWE-307] in Fortinet FortiMail version 6.4.0, version 6.2.0 through 6.2.4 and before 6.0.9 allows a remote unauthenticated attacker to partially exhaust CPU and memory via sending numerous HTTP requests to the login form. |
| An issue was discovered in Open Design Alliance Drawings SDK before 2023.3. An Out-of-Bounds Read vulnerability exists when reading a DWG file with an invalid vertex number in a recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process. |